When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Air flow bench - Wikipedia

    en.wikipedia.org/wiki/Air_flow_bench

    Most flow testing is done at 10 and 28 inches of water pressure (2.5 to 7 kilopascals). Although other test pressures will work, the results would have to be converted for comparison to the work of others. The pressure developed must account for the test pressure plus the loss across the metering element plus all other system losses.

  3. File:Air and Water Pump Indicator Diagram, 1869.jpg

    en.wikipedia.org/wiki/File:Air_and_Water_Pump...

    Main page; Contents; Current events; Random article; About Wikipedia; Contact us

  4. Thermodynamic pump testing - Wikipedia

    en.wikipedia.org/wiki/Thermodynamic_pump_testing

    Thermodynamic pump testing is a form of pump testing where only the temperature rise, power consumed, and differential pressure need to be measured to find the efficiency of a pump. These measurements are typically made with insertion temperature probes and pressure probes fitted to tapping points on the pump's inlet and outlet. [ 1 ]

  5. Indicator diagram - Wikipedia

    en.wikipedia.org/wiki/Indicator_diagram

    An indicator diagram is a chart used to measure the thermal, or cylinder, performance of reciprocating steam and internal combustion engines and compressors. [1] An indicator chart records the pressure in the cylinder versus the volume swept by the piston, throughout the two or four strokes of the piston which constitute the engine, or ...

  6. Air flow meter - Wikipedia

    en.wikipedia.org/wiki/Air_flow_meter

    An air flow meter is a device similar to an anemometer that measures air flow, i.e. how much air is flowing through a tube. It does not measure the volume of the air passing through the tube, it measures the mass of air flowing through the device per unit time, though Thus air flow meters are simply an application of mass flow meters for the ...

  7. Net positive suction head - Wikipedia

    en.wikipedia.org/wiki/Net_positive_suction_head

    Example Number 2: A well or bore with an operating level of 5 metres below the intake, minus a 2 metre friction loss into pump (pipe loss), minus the NPSH R curve (say 2.4 metres) of the pre-designed pump = an NPSH A (available) of (negative) -9.4 metres. Adding the atmospheric pressure of 10 metres gives a positive NPSH A of 0.6 metres.

  8. Pressure–volume diagram - Wikipedia

    en.wikipedia.org/wiki/Pressure–volume_diagram

    A PV diagram plots the change in pressure P with respect to volume V for some process or processes. Typically in thermodynamics, the set of processes forms a cycle, so that upon completion of the cycle there has been no net change in state of the system; i.e. the device returns to the starting pressure and volume.

  9. Hydrostatic test - Wikipedia

    en.wikipedia.org/wiki/Hydrostatic_test

    The test involves filling the vessel or pipe system with a liquid, usually water, which may be dyed to aid in visual leak detection, and pressurization of the vessel to the specified test pressure. Pressure tightness can be tested by shutting off the supply valve and observing whether there is a pressure loss.