A TOF mass spectrometer can also have a low-duty cycle when coupled with a continuous ion source. Combining an ion trap with a TOF mass analyzer can improve the duty cycle. Both 3D and linear traps have been combined with TOF mass analyzers. A trap can also add MSn capabilities to the system. [1]
An ion trap, used for precision measurements of radium ions, inside a vacuum chamber. View ports surrounding the chamber allow laser light to be directed into the trap. An ion trap is a combination of electric and/or magnetic fields used to capture charged particles — known as ions — often in a system isolated from an external environment.
This method of injection works well with pulsed sources such as MALDI but cannot be interfaced to continuous ion sources like electrospray. All commercial Orbitrap mass spectrometers utilize a curved linear trap for ion injection (C-trap). By rapidly ramping down trapping RF voltages and applying DC gradients across the C-trap, ions can be ...
The two Penning traps following the MR-ToF are the preparation Penning trap and the precision Penning trap. [4] The preparation Penning trap, a large cylindrical trap, is placed in the uniform field of a superconducting magnet. [13] [12] The ions are captured and, with high-selectivity, cooled by mass. [14]
The velocity of the charged particle after acceleration will not change since it moves in a field-free time-of-flight tube. The velocity of the particle can be determined in a time-of-flight tube since the length of the path (d) of the flight of the ion is known and the time of the flight of the ion (t) can be measured using a transient digitizer or time to digital converter.
For SSIMS the primary requirement is low primary ion flux density which results in extremely low secondary ion yield (10 −3 – 10 −8 atoms/cm³). Hence, there is a need to collect almost all the secondary ions. High transmission (0.5–1) of TOF maximizes the sensitivity (10 4 times that of quadrupole MS). Parallel detection together with ...
A sector instrument can be combined with a collision quadrupole and quadrupole mass analyzer to form a hybrid instrument. [1] A BEqQ configuration with a magnetic sector (B), electric sector (E), collision quadrupole (q) and m/z selection quadrupole (Q) have been constructed [2] [3] and an instrument with two electric sectors (BEEQ) has been described.
Time of flight (ToF) is the measurement of the time taken by an object, particle or wave (be it acoustic, electromagnetic, etc.) to travel a distance through a medium. This information can then be used to measure velocity or path length, or as a way to learn about the particle or medium's properties (such as composition or flow rate).