Ad
related to: ase guidelines for aortic measurements
Search results
Results From The WOW.Com Content Network
The left atrial volume is commonly measured by echocardiography or magnetic resonance tomography.It is calculated from biplane recordings with the equation: = where A4c and A2c denote LA areas in 4- and 2-chamber views respectively, and L corresponds to the shortest long-axis length measured in either views.
In cardiology, aortic valve area calculation is an indirect method of determining the area of the aortic valve of the heart. The calculated aortic valve orifice area is currently one of the measures for evaluating the severity of aortic stenosis. A valve area of less than 1.0 cm 2 is considered to be severe aortic stenosis. [1] [2]
Measurements in this view can be used to quantify the heart: Left ventricular size and wall thickness; Left atrial linear dimension (as opposed to area) Left ventricular outflow tract diameter (used to calculate aortic valve area by the continuity equation) Aortic annulus, sinus of Valsalva, and aortic root sizes; Color doppler of all four valves
By approximating the shape of the left atrium as an ellipsoid, its volume can be calculated from measurements of its dimensions along three perpendicular directions. [3] Indexing the left atrial volume to body surface area (volume/BSA) is recommended by the American Society of Echocardiography and the European Association of Echocardiography ...
The American Society of Echocardiography (ASE) is a professional organization made up of physicians, sonographers, nurses, and scientists involved in the field of echocardiography. One of the most important roles that the ASE plays is providing their recommendations through the ASE Guidelines and Standards, providing resource and educational ...
Intima–media thickness (IMT), also called intimal medial thickness, is a measurement of the thickness of tunica intima and tunica media, the innermost two layers of the wall of an artery. The measurement is usually made by external ultrasound and occasionally by internal, invasive ultrasound catheters .
Aortic regurgitation (AR), also known as aortic insufficiency (AI), is the leaking of the aortic valve of the heart that causes blood to flow in the reverse direction during ventricular diastole, from the aorta into the left ventricle. As a consequence, the cardiac muscle is forced to work harder than normal.
Impedance cardiography (ICG) is a non-invasive technology measuring total electrical conductivity of the thorax and its changes in time to process continuously a number of cardiodynamic parameters, such as stroke volume (SV), heart rate (HR), cardiac output (CO), ventricular ejection time (VET), pre-ejection period and used to detect the impedance changes caused by a high-frequency, low ...