When.com Web Search

  1. Ad

    related to: 2 ohm vs 4 subs to 5 watt transformer switch

Search results

  1. Results From The WOW.Com Content Network
  2. Bus coupler - Wikipedia

    en.wikipedia.org/wiki/Bus_coupler

    Normally bus couplers are available with 1.4:1 transformer ratios and 59 ohm (2 watt 1%) resistors. For special applications, couplers can be supplied with different transformer ratios (e.g., 1:1) and other resistance values (e.g., 54.9 ohms). Bus coupler configurations are available as non-terminated or internally terminated.

  3. Push–pull converter - Wikipedia

    en.wikipedia.org/wiki/Push–pull_converter

    For example, in a full-bridge converter, the switches (connected as an H-bridge) alternate the voltage across the supply side of the transformer, causing the transformer to function as it would for AC power and produce a voltage on its output side. However, push–pull more commonly refers to a two-switch topology with a split primary winding.

  4. Switched-mode power supply - Wikipedia

    en.wikipedia.org/wiki/Switched-mode_power_supply

    One of the two switches must be active (e.g., a transistor), while the other can be a diode. Sometimes, the topology can be changed simply by re-labeling the connections. A 12 V input, 5 V output buck converter can be converted to a 7 V input, −5 V output buck–boost by grounding the output and taking the output from the ground pin.

  5. Constant-voltage speaker system - Wikipedia

    en.wikipedia.org/wiki/Constant-voltage_speaker...

    600 watt transformers are widely available for contractors needing high power loudspeakers in constant-voltage installations. [12] Special-purpose transformers capable of handling 1250 watts down as low as 50 Hz are available. [4] One problem with high power, high current transformers is that fewer can be used on a single constant-voltage line.

  6. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    Another way to avoid the transformer inrush current is a "transformer switching relay". This does not need time for cool down. It can also deal with power-line half-wave voltage dips and is short-circuit-proof. This technique is important for IEC 61000-4-11 tests. Another option, particularly for high-voltage circuits, is to use a pre-charge ...

  7. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Substation - Wikipedia

    en.wikipedia.org/wiki/Substation

    Underneath a substation, a mat or grid of conductors laid around 0.5 or 0.6 metres (1 ft 8 in or 2 ft 0 in) underground provides grounding. [ 26 ] [ 27 ] This grid, which is typically copper although it may be galvanized iron in some countries, [ 27 ] is used to ground circuits that are being worked on to prevent accidental re-energization ...