When.com Web Search

  1. Ad

    related to: air changes per hour recommendation

Search results

  1. Results From The WOW.Com Content Network
  2. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour.

  3. Clean air delivery rate - Wikipedia

    en.wikipedia.org/wiki/Clean_Air_Delivery_Rate

    This recommendation is based on the assumption that the room will have air exchanged with other rooms at a rate of less than 1 room volume per hour, and that the customer desires at least 80% of the smoke particles removed from the air. For an 8-foot (2.4 m) high room, this means the room volume should be less than or equal to 12 times the CADR ...

  4. Indoor air quality - Wikipedia

    en.wikipedia.org/wiki/Indoor_air_quality

    The WHO recommended levels of indoor CO exposure in 24 hours is 4 mg/m 3. [29] Acute exposure should not exceed 10 mg/m 3 in 8 hours, ... not air changes per hour ...

  5. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    For residential buildings, which mostly rely on infiltration for meeting their ventilation needs, a common ventilation rate measure is the air change rate (or air changes per hour): the hourly ventilation rate divided by the volume of the space (I or ACH; units of 1/h). During the winter, ACH may range from 0.50 to 0.41 in a tightly air-sealed ...

  6. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    The infiltration rate is the volumetric flow rate of outside air into a building, typically in cubic feet per minute (CFM) or liters per second (LPS). The air exchange rate, (I), is the number of interior volume air changes that occur per hour, and has units of 1/h. The air exchange rate is also known as air changes per hour (ACH).

  7. Air quality guideline - Wikipedia

    en.wikipedia.org/wiki/Air_quality_guideline

    The reports provide guidelines intending to give guidelines to reduce the health effects of air pollution. [2] The guidelines stipulate that PM 2.5 should not exceed 5 μg/m 3 annual mean, or 15 μg/m 3 24-hour mean; and that PM 10 should not exceed 15 μg/m 3 annual mean, or 45 μg/m 3 24-hour mean. [2]

  8. Workplace hazard controls for COVID-19 - Wikipedia

    en.wikipedia.org/wiki/Workplace_hazard_controls...

    The CDC suggests that, in non-healthcare settings, building ventilation should be brought up to 5 air changes per hour, along with the use of MERV-13 filters, the use of air purifiers (air cleaners), and upper-room Ultraviolet germicidal irradiation (UVGI) to reduce the odds of infection and people coming down with COVID-19.

  9. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    The hourly ventilation rate divided by the volume of a space. For perfectly mixed air or laminar flow spaces, this is equal to the number of times per hour that the volume the space is exchanged by mechanical and natural ventilation. Also called air change rate or air exchange rate. Abbreviated ACH or ac/hr. air conditioner