The rem and millirem are CGS units in widest use among the U.S. public, industry, and government. [4] However, the SI unit the sievert (Sv) is the normal unit outside the United States, and is increasingly encountered within the US in academic, scientific, and engineering environments, and have now virtually replaced the rem. [5]
The SI unit of measure for equivalent dose is the sievert, defined as one Joule per kg. [11] In the United States the roentgen equivalent man (rem), equal to 0.01 sievert, is still in common use, although regulatory and advisory bodies are encouraging transition to sievert. [12]
Effective dose is a dose quantity in the International Commission on Radiological Protection (ICRP) system of radiological protection. [1]It is the tissue-weighted sum of the equivalent doses in all specified tissues and organs of the human body and represents the stochastic health risk to the whole body, which is the probability of cancer induction and genetic effects, of low levels of ...
Count rate does not universally equate to dose rate, and there is no simple universal conversion factor. Any conversions are instrument-specific. Counts is the number of events detected, but dose rate relates to the amount of ionising energy deposited in the sensor of the radiation detector. The conversion calculation is dependent on the ...
The sievert is named after Rolf Maximilian Sievert. As with every SI unit named for a person, its symbol starts with an upper case letter (Sv), but when written in full, it follows the rules for capitalisation of a common noun; i.e., sievert becomes capitalised at the beginning of a sentence and in titles but is otherwise in lower case.
Absorbed dose is a dose quantity which is the measure of the energy deposited in matter by ionizing radiation per unit mass.Absorbed dose is used in the calculation of dose uptake in living tissue in both radiation protection (reduction of harmful effects), and radiology (potential beneficial effects, for example in cancer treatment).
The ICRP 2007 standard values for relative effectiveness are given below. The higher radiation weighting factor for a type of radiation, the more damaging it is, and this is incorporated into the calculation to convert from gray to sievert units. The radiation weighting factor for neutrons has been revised over time and remains controversial.
That model calculates an effective radiation dose, measured in units of rem, which is more representative of the stochastic risk than the absorbed dose in rad. In most power plant scenarios, where the radiation environment is dominated by X-or gamma rays applied uniformly to the whole body, 1 rad of absorbed dose gives 1 rem of effective dose. [5]