When.com Web Search

  1. Ad

    related to: iv drop per minute formula machining center for small space air conditioners

Search results

  1. Results From The WOW.Com Content Network
  2. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.

  3. Speeds and feeds - Wikipedia

    en.wikipedia.org/wiki/Speeds_and_feeds

    Cutting speed may be defined as the rate at the workpiece surface, irrespective of the machining operation used. A cutting speed for mild steel of 100 ft/min is the same whether it is the speed of the cutter passing over the workpiece, such as in a turning operation, or the speed of the cutter moving past a workpiece, such as in a milling operation.

  4. Vortex tube - Wikipedia

    en.wikipedia.org/wiki/Vortex_tube

    With no moving parts, no electricity, and no refrigerant, a vortex tube can produce refrigeration up to 1,800 W (6,000 BTU/h) using 100 standard cubic feet per minute (2.832 m 3 /min) of filtered compressed air at 100 psi (6.9 bar). A control valve in the hot air exhaust adjusts temperatures, flows and refrigeration over a wide range.

  5. Hagen–Poiseuille equation - Wikipedia

    en.wikipedia.org/wiki/Hagen–Poiseuille_equation

    It can be successfully applied to air flow in lung alveoli, or the flow through a drinking straw or through a hypodermic needle. It was experimentally derived independently by Jean Léonard Marie Poiseuille in 1838 [ 1 ] and Gotthilf Heinrich Ludwig Hagen , [ 2 ] and published by Hagen in 1839 [ 1 ] and then by Poiseuille in 1840–41 and 1846 ...

  6. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Clean air delivery rate (CADR) is the amount of clean air an air cleaner provides to a room or space. When determining CADR, the amount of airflow in a space is taken into account. For example, an air cleaner with a flow rate of 30 cubic metres (1,000 cu ft) per minute and an efficiency of 50% has a CADR of 15 cubic metres (500 cu ft) per minute.

  7. Milling (machining) - Wikipedia

    en.wikipedia.org/wiki/Milling_(machining)

    Milling centers are generally classified as vertical machining centers (VMCs) or horizontal machining centers (HMCs). The integration of milling into turning environments, and vice versa, began with live tooling for lathes and the occasional use of mills for turning operations. This led to a new class of machine tools, multitasking machines ...

  8. Machinability - Wikipedia

    en.wikipedia.org/wiki/Machinability

    Machinability is the ease with which a metal can be cut permitting the removal of the material with a satisfactory finish at low cost. [1] Materials with good machinability (free machining materials) require little power to cut, can be cut quickly, easily obtain a good finish, and do not cause significant wear on the tooling.

  9. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    The hourly ventilation rate divided by the volume of a space. For perfectly mixed air or laminar flow spaces, this is equal to the number of times per hour that the volume the space is exchanged by mechanical and natural ventilation. Also called air change rate or air exchange rate. Abbreviated ACH or ac/hr. air conditioner