When.com Web Search

  1. Ads

    related to: how to duct an erv 2 box with water connection 1 6 10

Search results

  1. Results From The WOW.Com Content Network
  2. Heat recovery ventilation - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_ventilation

    Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...

  3. Central vacuum cleaner - Wikipedia

    en.wikipedia.org/wiki/Central_vacuum_cleaner

    However, that manufacturer has also switched to the de facto industry standard size of 2-inch (5.1 cm) outside diameter piping and corresponding fittings. In most cases, the end user need not be aware of the piping size in a central vacuum system, but the piping size must be considered when extending, modifying, or repairing a system.

  4. Process duct work - Wikipedia

    en.wikipedia.org/wiki/Process_Duct_Work

    Round duct elbow allowable stresses are lower than the allowable stresses for straight duct by a K factor = 1.65/(h 2/3power) where h = t (duct) * R (elbow) /(r(duct)*r (duct). This equation, or similar equations is found in Tubular Steel Structures section 9.9. Rectangular ductwork design properties is based on width-to-thickness ratios.

  5. Air-mixing plenum - Wikipedia

    en.wikipedia.org/wiki/Air-mixing_plenum

    An air handling unit used for the heating and cooling air: (1) supply air (2) fan section (3) vibration isolator (4) cooling coil (5) filter (6) mixed air duct. Air supply to a building is generally performed by an air handling unit. The process may include filtering, heating, cooling, humidification, or dehumidification, all of which consume ...

  6. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.

  7. Air handler - Wikipedia

    en.wikipedia.org/wiki/Air_handler

    An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning system. [1] An air handler is usually a large metal box containing a blower, furnace or A/C elements, filter racks or chambers, sound attenuators, and dampers. [2]