A link budget is an accounting of all of the power gains and losses that a communication signal experiences in a telecommunication system; from a transmitter, through a communication medium such as radio waves, cable, waveguide, or optical fiber, to the receiver.
In figure 21, an example is shown of a signal split up to feed multiple low power amplifiers, then recombined to feed a single antenna with high power. [52] Figure 21. Splitter and combiner networks used with amplifiers to produce a high power 40 dB (voltage gain 100) solid state amplifier Figure 22. Phase arrangement on a hybrid power combiner.
The FBT splitter is one of the most common. FBT splitters are widely accepted and used in passive networks, especially for instances where the split configuration is smaller (1×2, 1×4, 2×2, etc.). [1] The PLC is a more recent technology. PLC splitters offer a better solution for larger applications.
Return loss is a measure of how well devices or lines are matched. A match is good if the return loss is high. A high return loss is desirable and results in a lower insertion loss. From a certain perspective 'Return Loss' is a misnomer. The usual function of a transmission line is to convey power from a source to a load with minimal loss.
Insertion loss, also referred to as attenuation, refers to the loss of signal strength at the far end of a line compared to the signal that was introduced into the line. This loss is due to the electrical resistance of the copper cable , the loss of energy through the cable insulation, and impedance mismatches introduced at the connectors.
In North America, this reverse signal is a modulated RF ranging from 5–42 MHz while in other parts of the world, the range is 5–65 MHz. This electrical signal is then outputted through coaxial cable to form a coaxial trunk. The optical portion of the network provides a large amount of flexibility.
ANSI/TIA-568 is a technical standard for commercial building cabling for telecommunications products and services. The title of the standard is Commercial Building Telecommunications Cabling Standard and is published by the Telecommunications Industry Association (TIA), a body accredited by the American National Standards Institute (ANSI).
Signal terminators are designed to specifically match the characteristic impedances at both cable ends. For many systems, the terminator is a resistor , with a value chosen to match the characteristic impedance of the transmission line and chosen to have acceptably low parasitic inductance and capacitance at the frequencies relevant to the system.