  1. Ads

    related to: generator hookup into main panel kit

Search results

  1. Results From The WOW.Com Content Network
  2. Generator interlock kit - Wikipedia

    en.wikipedia.org/wiki/Generator_Interlock_Kit

    The external mains feeds the panel, but the panel cannot backfeed the generator. Backfeeding the generator should never be done, because it serves no purpose and risks damaging the generator. In generator mode, the backfeed breaker is on, accepting power from the generator into the panel, and the main breaker is off, isolating the external ...

  3. Backfeeding - Wikipedia

    en.wikipedia.org/wiki/Backfeeding

    A common source of unintentional backfeeding is an electrical generator (typically a portable generator) that is improperly connected to a building electrical system.A properly installed electrical generator incorporates the use of a transfer switch or generator interlock kit to ensure the incoming electrical service line is disconnected when the generator is providing power to the building.

  4. Engine–generator - Wikipedia

    en.wikipedia.org/wiki/Engine–generator

    An engine–generator is the combination of an electrical generator and an engine (prime mover) mounted together to form a single piece of equipment. This combination is also called an engine–generator set or a gen-set. In many contexts, the engine is taken for granted and the combined unit is simply called a generator. An engine–generator ...

  5. Isolated-phase bus - Wikipedia

    en.wikipedia.org/wiki/Isolated-phase_bus

    The consequences of a two- or three-phase fault between the generator and the first circuit breaker are therefore much more serious and often result in severe damage to the busbars and nearby equipment. Isolated-phase bus is made in ratings from 3000 amperes to 45,000 amperes, and rated for voltages from 5000 volts up to about 35,000 volts.

  6. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    During installation of a generator, careful checks are made to ensure the generator terminals and all control wiring is correct so that the order of phases (phase sequence) matches the system. Connecting a generator with the wrong phase sequence will result in large, possibly damaging, currents as the system voltages are opposite to those of ...