When.com Web Search

  1. Ads

    related to: checking refrigerant charge with gauges

Search results

  1. Results From The WOW.Com Content Network
  2. Thermal expansion valve - Wikipedia

    en.wikipedia.org/wiki/Thermal_expansion_valve

    A thermal expansion valve or thermostatic expansion valve (often abbreviated as TEV, TXV, or TX valve) is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator ...

  3. Suction pressure - Wikipedia

    en.wikipedia.org/wiki/Suction_pressure

    In refrigeration and air conditioning systems, the suction pressure' (also called the low-side pressure) is the intake pressure generated by the system compressor while operating. The suction pressure, along with the suction temperature the wet bulb temperature of the discharge air are used to determine the correct refrigerant charge in a system.

  4. R-410A - Wikipedia

    en.wikipedia.org/wiki/R-410A

    R-410A is a refrigerant used in air conditioning and heat pump applications. It is a zeotropic but near-azeotropic mixture of difluoromethane (CH 2 F 2, called R-32) and pentafluoroethane (CHF 2 CF 3, called R-125). R-410A is sold under the trademarked names AZ-20, EcoFluor R410, Forane 410A, Genetron R410A, Puron, and Suva 410A.

  5. Vapor-compression refrigeration - Wikipedia

    en.wikipedia.org/.../Vapor-compression_refrigeration

    A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.

  6. Tracer-gas leak testing - Wikipedia

    en.wikipedia.org/wiki/Tracer-gas_leak_testing

    On planes, tracer-gas leak testing is used to quickly and safely locate fuel leaks, [3] as well as to check oxygen distribution devices and cabin pressurization systems. Refrigeration and air conditioning must have the lowest possible rate of loss of refrigerant gases (contributing to ozone depletion ).

  7. Sight glass - Wikipedia

    en.wikipedia.org/wiki/Sight_glass

    Water gauge on a steam locomotive. Here the water is at the “top nut”, the maximum working level. Note the patterned backplate to help reading and toughened glass shroud. A sight glass or water gauge is a type of level sensor, a transparent tube through which the operator of a tank or boiler can observe the level of liquid contained within.