Normal boiling points for pure substances, bubble and dew points for zeotropic blends, or normal boiling point and azeotropic temperature for the azeotropic blends, at 101,325 Pa (1 atmosphere) and in degrees Celsius; Critical temperature in degrees Celsius; Absolute critical pressure in kilopascals
R-422C is for use in medium- and low-temperature applications. The TXV power element will need to be changed to a 404A/507A element and critical seals (elastomers) may need to be replaced. R-422D is for use in low-temp applications, and is mineral oil compatible.
Difluoromethane serves to provide the heat capacity, pentafluoroethane decreases flammability, tetrafluoroethane reduces pressure. [1] R-407C cylinders are colored burnt orange . This refrigerant is intended as a replacement for R-22 .
From 1930 to 1935, they developed dichlorodifluoromethane (CCl 2 F 2 or R12), trichlorofluoromethane (CCl 3 F or R11), chlorodifluoromethane (CHClF 2 or R22), trichlorotrifluoroethane (CCl 2 FCClF 2 or R113), and dichlorotetrafluoroethane (CClF 2 CClF 2 or R114), through Kinetic Chemicals which was a joint venture between DuPont and General Motors.
A refrigerant needs to have: a boiling point that is somewhat below the target temperature (although boiling point can be adjusted by adjusting the pressure appropriately), a high heat of vaporization, a moderate density in liquid form, a relatively high density in gaseous form (which can also be adjusted by setting pressure appropriately), and ...
Vapor pressure 90 psi (6.1 atm) at 23 °C, yielding breakdown voltage 17 times higher than air at 1 atm. Higher breakdown voltages can be achieved by increasing pressure by adding nitrogen. Corrosive decomposition products. Trifluoromethane: CF 3 H: 0.8: weak 1,1,1,3,3,3-Hexafluoropropane (R-236fa) CF 3 CH 2 CF 3: 152.05: 6300 strong
At the start of the thermodynamic cycle the refrigerant enters the compressor as a low pressure and low temperature vapor. In heat pumps, this refrigerant is typically R32 refrigerant or R290 refrigerant. Then the pressure is increased and the refrigerant leaves as a higher temperature and higher pressure superheated gas.
A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.