Results From The WOW.Com Content Network
Hydrophilic interaction chromatography (or hydrophilic interaction liquid chromatography, HILIC) [1] is a variant of normal phase liquid chromatography that partly overlaps with other chromatographic applications such as ion chromatography and reversed phase liquid chromatography. HILIC uses hydrophilic stationary phases with reversed-phase ...
Pliska and his coworkers [27] used thin layer chromatography to relate mobility values of free amino acids to their hydrophobicities. About a decade ago, another hydrophilicity scale was published, this scale used normal phase liquid chromatography and showed the retention of 121 peptides on an amide-80 column. [28]
Reversed-phase liquid chromatography (RP-LC) is a mode of liquid chromatography in which non-polar stationary phase and polar mobile phases are used for the separation of organic compounds. [ 1 ] [ 2 ] [ 3 ] The vast majority of separations and analyses using high-performance liquid chromatography (HPLC) in recent years are done using the ...
A faster method of log P determination makes use of high-performance liquid chromatography. The log P of a solute can be determined by correlating its retention time with similar compounds with known log P values. [40] An advantage of this method is that it is fast (5–20 minutes per sample).
Chromatographic peak resolution is given by = + where t R is the retention time and w b is the peak width at baseline. The bigger the time-difference and/or the smaller the bandwidths, the better the resolution of the compounds.
The fundamental resolution equation is used in chromatography to help relate adjustable chromatographic parameters to resolution, and is as follows: . R s = [N 1/2 /4][(α-1)/α][k 2 '/(1+k 2 ')], where
Most of the current methods of separation of biomedical materials use C-18 type of columns, sometimes called by a trade names such as ODS (octadecylsilane) or RP-18 (Reversed Phase 18). The most common RP stationary phases are based on a silica support, which is surface-modified by bonding RMe 2 SiCl, where R is a straight chain alkyl group ...
A hydrophilicity plot is a quantitative analysis of the degree of hydrophobicity or hydrophilicity of amino acids of a protein.It is used to characterize or identify possible structure or domains of a protein.