When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Ultrasonography of chronic venous insufficiency of the legs

    en.wikipedia.org/wiki/Ultrasonography_of_chronic...

    The reflected ultrasound is received by the probe, transformed into an electric impulse as voltage, and sent to the engine for signal processing and conversion to an image on the screen. The depth reached by the ultrasound beam is dependent on the frequency of the probe used. The higher the frequency, the lesser the depth reached. [9]

  3. Doppler ultrasonography - Wikipedia

    en.wikipedia.org/wiki/Doppler_ultrasonography

    The disadvantage of pulsed Doppler is that the measurements can suffer from aliasing. The terms Doppler ultrasound and Doppler sonography have been accepted to apply to both pulsed and continuous Doppler systems, despite the different mechanisms by which the velocity is measured. [citation needed] There are no standards for displaying color ...

  4. Ankle–brachial pressure index - Wikipedia

    en.wikipedia.org/wiki/Ankle–brachial_pressure...

    A Doppler ultrasound blood flow detector, commonly called Doppler wand or Doppler probe, and a sphygmomanometer (blood pressure cuff) are usually needed. The blood pressure cuff is inflated proximal to the artery in question. Measured by the Doppler wand, the inflation continues until the pulse in the artery ceases.

  5. E/A ratio - Wikipedia

    en.wikipedia.org/wiki/E/A_ratio

    The E/A ratio is a marker of the function of the left ventricle of the heart. It represents the ratio of peak velocity blood flow from left ventricular relaxation in early diastole (the E wave) to peak velocity flow in late diastole caused by atrial contraction (the A wave). [1]

  6. Speckle tracking echocardiography - Wikipedia

    en.wikipedia.org/wiki/Speckle_Tracking...

    [15] [16] [17] Tissue Doppler technology, the alternative method for strain rate imaging to speckle tracking technology, requires achieving sufficient parallel orientation between the direction of motion and the ultrasound beam. Its use has remained limited due to angle dependency, substantial intraobserver and interobserver variability and ...

  7. Ultrasonography of deep vein thrombosis - Wikipedia

    en.wikipedia.org/wiki/Ultrasonography_of_deep...

    Doppler ultrasonography showing absence of flow and hyperechogenic content in deep vein thrombosis of the subsartorial vein. Coronal plane, seen from medial side of lower leg, showing thrombosis of the fibular veins , with hyperechoic content and only marginal blood flow.

  8. Transthoracic echocardiogram - Wikipedia

    en.wikipedia.org/wiki/Transthoracic_echocardiogram

    A transthoracic echocardiogram (TTE) is the most common type of echocardiogram, which is a still or moving image of the internal parts of the heart using ultrasound.In this case, the probe (or ultrasonic transducer) is placed on the chest or abdomen of the subject to get various views of the heart.

  9. Therapeutic ultrasound - Wikipedia

    en.wikipedia.org/wiki/Therapeutic_ultrasound

    Ultrasound can ablate tumors or other tissue non-invasively. [4] This is accomplished using a technique known as high intensity focused ultrasound (HIFU), also called focused ultrasound surgery. This procedure uses generally lower frequencies than medical diagnostic ultrasound (250–2000 kHz), but significantly higher time-averaged intensities.