    ACI Code 7.10.4.2: For cast-in-place construction, size of spirals shall not be less than 3/8 in. diameter. ACI Code 7.10.4.3: Clear spacing between spirals shall not exceed 3 in., nor be less than 1in. Section 10.9.3 adds an additional lower limit to the amount of spiral reinforcement via the volumetric spiral reinforcement ratio ρ s.

  3. Waffle slab - Wikipedia

    en.wikipedia.org/wiki/Waffle_slab

    The distance between ribs is typically 915 mm (3 ft). [3] The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3] The width of the solid area around the column should be 1 ⁄ 8 of the span between columns. Its height should be the same as the ribs. [3] Diagram showing waffle slab rib and Beam Heights rule of thumb ...

  4. Reinforced concrete - Wikipedia

    en.wikipedia.org/wiki/Reinforced_concrete

    (2) The thermal expansion coefficients of concrete and steel are so close (1.0 × 10 −5 to 1.5 × 10 −5 for concrete and 1.2 × 10 −5 for steel) that the thermal stress-induced damage to the bond between the two components can be prevented. (3) Concrete can protect the embedded steel from corrosion and high-temperature induced softening.

  5. Eurocode 2: Design of concrete structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_2:_Design_of...

    EN 1992-1-2 deals with the design of concrete structures for the accidental situation of fire exposure and is intended to be used in conjunction with EN 1992-1-1 and EN 1991-1-2. This part 1-2 only identifies differences from, or supplements to, normal temperature design. Part 1-2 of EN 1992 deals only with passive methods of fire protection.

  6. Concrete frame - Wikipedia

    en.wikipedia.org/wiki/Concrete_frame

    A concrete frame, also known as a concrete skeleton, is a structure composed of interconnected beams, columns, and slabs that is used to support larger structures. [ 1 ] [ 2 ] Due to the low cost of producing them, concrete frames are often used when building damns, bridges, and buildings.

  7. Euler's critical load - Wikipedia

    en.wikipedia.org/wiki/Euler's_critical_load

    Fig. 2: Column effective length factors for Euler's critical load. In practical design, it is recommended to increase the factors as shown above. The following assumptions are made while deriving Euler's formula: [3] The material of the column is homogeneous and isotropic. The compressive load on the column is axial only.

  8. Anchorage in reinforced concrete - Wikipedia

    en.wikipedia.org/wiki/Anchorage_in_Reinforced...

    Reinforced concrete is concrete in which reinforcement bars ("rebars"), reinforcement grids, plates or fibers are embedded to create bond and thus to strengthen the concrete in tension. The composite material was invented by French gardener Joseph Monier in 1849 and patented in 1867. [1]

  9. Reinforced concrete structures durability - Wikipedia

    en.wikipedia.org/wiki/Reinforced_concrete...

    Initiation and propagation periods of steel rebar corrosion in a reinforced concrete structure (Tutti diagram). [2] [3] Initially, the chemical reactions that normally occur in the cement paste, generate an alkaline environment, bringing the solution in the cement paste pores to pH values around 13. In these conditions, passivation of steel ...