When.com Web Search

  1. Ads

    related to: transformer partial discharge test device price

Search results

  1. Results From The WOW.Com Content Network
  2. Partial discharge - Wikipedia

    en.wikipedia.org/wiki/Partial_discharge

    Data collected during partial discharge testing is compared to measurement values of the same cable gathered during the acceptance-test or to factory quality control standards. This allows simple and quick classification of the dielectric condition (new, strongly aged, faulty) of the device under test and appropriate maintenance and repair ...

  3. Dissolved gas analysis - Wikipedia

    en.wikipedia.org/wiki/Dissolved_gas_analysis

    An oil sample tube is used to draw, retain and transport the sample of transformer oil in the same condition as it is inside a transformer with all fault gases dissolved in it. It is a gas tight borosilicate glass tube of capacity 150 ml or 250 ml, having two airtight Teflon valves on both the ends.

  4. VLF cable testing - Wikipedia

    en.wikipedia.org/wiki/VLF_cable_testing

    Apply VLF in order to detect and measure partial discharge. In this case, the IEEE 400.3 outlines a procedure for assessment and IEC 60270 provides the background for partial discharge testing of high voltage apparatus. The test is typically performed over a range of test voltages to identify the different defects and their inception and ...

  5. Electrical treeing - Wikipedia

    en.wikipedia.org/wiki/Electrical_treeing

    An analysis of the PD signals collected during the measurement with the proper equipment can allow for the vast majority of location of insulation defects. Usually they are displayed in a partial discharge mapping format. Additional useful information about the device under test can be derived from a phase related depiction of the partial ...

  6. Corona discharge - Wikipedia

    en.wikipedia.org/wiki/Corona_discharge

    A corona discharge is an electrical discharge caused by the ionization of a fluid such as air surrounding a conductor carrying a high voltage. It represents a local region where the air (or other fluid) has undergone electrical breakdown and become conductive, allowing charge to continuously leak off the conductor into the air.

  7. Corona ring - Wikipedia

    en.wikipedia.org/wiki/Corona_ring

    The electric field at the surface of a conductor is greatest where the curvature is sharpest, so corona discharge occurs first at sharp points, corners and edges. The terminals on very high voltage equipment are frequently designed with large diameter rounded shapes such as balls and toruses called corona caps , to suppress corona formation.

  1. Ads

    related to: transformer partial discharge test device price