NEC states that the neutral and ground wires should be connected at the neutral point of the transformer or generator, or otherwise some "system neutral point" but not anywhere else. [1] That is for simple single panel installations; for multiple panels the situation is more complex.
NEMA L14 are three-pole and ground connectors rated for 125/250 V. Intended for three-pole, four-wire hot-hot-neutral-ground circuits with a nominal supply voltages of 240 or 208 V hot-to-hot and 120 V hot-to-neutral. These connectors are common on household backup generators, and on racks of power amplifiers in large audio systems.
The ground tab is designed to be attached to the outlet faceplate screw, which is supposed to be connected to the building electrical ground. A cheater plug, AC ground lifter or three-prong/two-prong adapter is an adapter that allows a NEMA 5-15P grounding-type plug (three prongs) to connect to a NEMA 1-15R non-grounding receptacle (two slots).
Higher current plugs have more lugs to prevent them from being inserted into a lower current socket outlet, while still allowing them to be inserted into a socket outlet of the same size group rated for a higher current. For example, a 32 A 4-pin plug without neutral can plug into a 50 A 5-pin socket with neutral available.
The National Electric Code (NEC) only specifies colors for ground and neutral: Green for the equipment grounding (safety) conductor (NEC Article 250.119), and white or grey for the neutral (grounded) conductor (NEC Article 200.6). These colors may not be used for any other purpose, nor may their purpose use a different color.
The neutral is connected to the center tap of the power company transformer of a split-phase system, or the center of the wye connection of a polyphase power system. United States electrical codes require that the neutral be connected to earth at the "service panel" only and at no other point within the building wiring system.
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
The US National Electrical Code permitted the use of the supply neutral wire as the equipment enclosure connection to ground from 1947 to 1996 for ranges (including separate cooktops and ovens) and from 1953 to 1996 for clothes dryers, provided that the circuit originated in the main service panel. Plug-in equipment and permanently connected ...