The flange design, inner and outer conductor dimensions are standardized, by EIA, in the RS-225, 50 Ω (ohm), and RS-259, 75 Ω, standards.They are commonly referred to by the inner diameter of the outer conductor in fractional inches.
The fitting is known as a reducing coupling, reducer, or adapter if their sizes differ. There are two types of collars: "regular" and "slip". A regular coupling has a small ridge or stops internally to prevent the over-insertion of a pipe and, thus, under-insertion of the other pipe segment (which would result in an unreliable connection).
Soft (or ductile) copper tubing can be bent easily to travel around obstacles in the path of the tubing. While the work hardening of the drawing process used to size the tubing makes the copper hard or rigid, it is carefully annealed to make it soft again; it is, therefore, more expensive to produce than non-annealed, rigid copper tubing.
It is also one of the standard couplings on fire hoses in Australia and the United States. The Storz coupling system is also widely used for filling of bulk wood pellet storage systems in Europe (Storz-A or 4-inch or 10-centimetre size), although in France and Belgium the equivalent Guillemin coupling is more commonly employed.
A coupling whose ends use the same connection method but are of different sizes is called a reducing coupling or reducer. An example is a 3/4" NPT to 1/2" NPT coupling. An example is a 3/4" NPT to 1/2" NPT coupling.
At its annual convention at Dallas, TX, the NFPA formally adopted a standard with 2 + 1 ⁄ 2-inch hose with 7.5 threads per inch as the primary standard, with additional sizes of 3 and 3.5 inches (each with 6 threads per inch) and a 4.5 inch coupling with 4 threads per inch, with the fire hydrant standard specifying one 4.5 inch port and two 2 ...
AN sizes range from -2 (dash two) to -32 in irregular steps, with each step equating to the OD (outside diameter) of the tubing in 1 ⁄ 16-inch increments. Therefore, a -8 AN size would be equal to 1 ⁄ 2-inch OD tube. However, this system does not specify the ID (inside diameter) of the tubing because the tube wall can vary in thickness.
Cam and groove fittings are commonly available in several materials, including stainless steel, aluminum, brass, and polypropylene. [2] Because there are no threads to become fouled, cam and groove couplings are popular in moderately dirty environments, such as septic tank pump trucks and chemical or fuel tanker trucks.