A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...
The committee's initial report evolved into NFPA 13, Standard for the Installation of Sprinkler Systems, the most widely used fire sprinkler standard. [ 6 ] Around 1904, the NFPA began to expand its membership from affiliates of fire insurance companies to many other organizations and individuals, and also expanded its mission beyond ...
A fire sprinkler mounted on a ceiling. A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year.
Fire sprinkler systems [ edit ] A fire sprinkler system is an active fire protection method, consisting of a water supply system, providing adequate pressure and flowrate to a water distribution piping system, onto which fire sprinklers are connected.
The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance. [3]
Wet systems are becoming less common with the increase in number of sprinkler systems being installed. [4] In some systems, firefighters have the option of pumping a Fire Department Connection (FDC) which will increase the water pressure at a standpipe in the event of a fire pump failure or loss of pressure.
A sprinkler system having pressurized air (rather than water) in the distribution pipes until a heat-activated sprinkler head opens and releases the stored air pressure, which in turn opens the main water valve (and possibly an accelerator valve) to flow water to the open sprinkler(s); used where the protected premises are not heated during ...
The practice of final fire sprinkler systems design and hydraulic calculations is commonly performed by design technicians who are often educated in-house at contracting firms throughout North America, with the objective of preparing designers for certification by testing by associations such as NICET (National Institute for Certification in ...