The type of oxygen sensor used in most underwater diving applications is the electro-galvanic oxygen sensor, a type of fuel cell, which is sometimes called an oxygen analyser or ppO 2 meter. They are used to measure the oxygen concentration of breathing gas mixes such as nitrox and trimix . [ 9 ]
A pulse oximeter probe applied to a person's finger. A pulse oximeter is a medical device that indirectly monitors the oxygen saturation of a patient's blood (as opposed to measuring oxygen saturation directly through a blood sample) and changes in blood volume in the skin, producing a photoplethysmogram that may be further processed into other measurements. [4]
To perform the test, one set of electrodes are placed on viable tissue (e.g. the chest) as a control and a second set is placed around the tissue in question (e.g. legs or feet). The electrodes may mildly heat the skin to increase blood flow into the area. Oxygen may also be given to the patient to see if that increases oxygen levels in the tissue.
Venous oxygen saturation (SvO 2) is the percentage of oxygenated hemoglobin returning to the right side of the heart. It can be measured to see if oxygen delivery meets the tissues' demands. SvO 2 typically varies between 60% and 80%. [9] A lower value indicates that the body is in lack of oxygen, and ischemic diseases occur.
Dissolved oxygen levels required by various species in the Chesapeake Bay (US). In aquatic environments, oxygen saturation is a ratio of the concentration of "dissolved oxygen" (DO, O 2), to the maximum amount of oxygen that will dissolve in that water body, at the temperature and pressure which constitute stable equilibrium conditions.
The oxygen content of a stored gas mixture can be analysed by passing a small flow of the gas over a recently calibrated cell for long enough that the output stabilises. The stable output represents the fraction of oxygen in the mixture. Care must be taken to ensure that the gas flow is not diluted by ambient air, as this would affect the reading.
Finger tip carboxyhemoglobin saturation monitor.. A CO-oximeter is a device that measures the oxygen carrying state of hemoglobin in a blood specimen, including oxygen-carrying hemoglobin (O2Hb), non-oxygen-carrying but normal hemoglobin (HHb) (formerly, but incorrectly, referred to as 'reduced' hemoglobin), as well as the dyshemoglobins such as carboxyhemoglobin (COHb) and methemoglobin (MetHb).
The constant, 1.36, is the amount of oxygen (ml at 1 atmosphere) bound per gram of hemoglobin. The exact value of this constant varies from 1.34 to 1.39, depending on the reference and the way it is derived. S a O 2 refers to the percent of arterial hemoglobin that is saturated with oxygen. The constant 0.0031 represents the amount of oxygen ...