Ad
related to: oxygen sensor readings explained pdf printable form
Search results
Results From The WOW.Com Content Network
The type of oxygen sensor used in most underwater diving applications is the electro-galvanic oxygen sensor, a type of fuel cell, which is sometimes called an oxygen analyser or ppO 2 meter. They are used to measure the oxygen concentration of breathing gas mixes such as nitrox and trimix . [ 9 ]
Pulse oximetry is a noninvasive method for monitoring blood oxygen saturation. Peripheral oxygen saturation (SpO 2) readings are typically within 2% accuracy (within 4% accuracy in 95% of cases) of the more accurate (and invasive) reading of arterial oxygen saturation (SaO 2) from arterial blood gas analysis.
The oxygen content of a stored gas mixture can be analysed by passing a small flow of the gas over a recently calibrated cell for long enough that the output stabilises. The stable output represents the fraction of oxygen in the mixture. Care must be taken to ensure that the gas flow is not diluted by ambient air, as this would affect the reading.
To perform the test, one set of electrodes are placed on viable tissue (e.g. the chest) as a control and a second set is placed around the tissue in question (e.g. legs or feet). The electrodes may mildly heat the skin to increase blood flow into the area. Oxygen may also be given to the patient to see if that increases oxygen levels in the tissue.
Dissolved oxygen levels required by various species in the Chesapeake Bay (US). In aquatic environments, oxygen saturation is a ratio of the concentration of "dissolved oxygen" (DO, O 2), to the maximum amount of oxygen that will dissolve in that water body, at the temperature and pressure which constitute stable equilibrium conditions.
A photoplethysmogram (PPG) is an optically obtained plethysmogram that can be used to detect blood volume changes in the microvascular bed of tissue. [1] [2] A PPG is often obtained by using a pulse oximeter which illuminates the skin and measures changes in light absorption. [3]
When a MAF sensor is used in conjunction with an oxygen sensor, the engine's air/fuel ratio can be controlled very accurately. The MAF sensor provides the open-loop controller predicted air flow information (the measured air flow) to the ECU, and the oxygen sensor provides closed-loop feedback in order to make minor corrections to the predicted ...
Fraction of inspired oxygen (F I O 2), correctly denoted with a capital I, [1] is the molar or volumetric fraction of oxygen in the inhaled gas. Medical patients experiencing difficulty breathing are provided with oxygen-enriched air, which means a higher-than-atmospheric F I O 2. Natural air includes 21% oxygen, which is equivalent to F I O 2 ...