Ads
related to: moisture content calculator formula for concrete floors free
Search results
Results From The WOW.Com Content Network
There is no ASTM standard for using a concrete moisture meter to determine a final moisture content reading. Concrete moisture meters, [4] either non-pin or pin meters are affected by what it sees in the concrete. This can be anything from the density of the concrete and aggregate size to the chemical properties of the slab.
Flow table with a grip and a hinge, 70 centimetres (28 in) square. In the American version of this test, the table is 10 inches (25 cm) diameter per ASTM C 230.; Abrams cone, open at the top and at the bottom - 30 centimetres (12 in) high, 17 centimetres (6.7 in) top diameter, 25 centimetres (9.8 in) base diameter.
Water content or moisture content is the quantity of water contained in a material, such as soil (called soil moisture), rock, ceramics, crops, or wood. Water content is used in a wide range of scientific and technical areas, and is expressed as a ratio, which can range from 0 (completely dry) to the value of the materials' porosity at saturation.
Interstitial condensation is a type of condensation that may occur within an enclosed wall, roof or floor cavity structure, which can create dampening.. When moisture-laden air at dew point temperature penetrates inside a cavity of the structure, it condenses into liquid water on that surface.
Calculation of the true sorptivity required numerical iterative procedures dependent on soil water content and diffusivity. John R. Philip (1969) showed that sorptivity can be determined from horizontal infiltration where water flow is mostly controlled by capillary absorption: I = S t {\displaystyle I=S{\sqrt {t}}} where S is sorptivity and I ...
A moisture meter gives a reading of the approximate moisture content of wood. The reading helps in determining whether the wood is suitably dry for its intended purpose. The moisture content reading can also assist in planning a project design that will accommodate future changes in dimension caused by changes in relative humidity.
The moisture content of grains is an essential property in food storage. The moisture content that is safe for long-term storage is 12% for corn, sorghum, rice and wheat and 11% for soybean [1] At a constant relative humidity of air, the EMC will drop by about 0.5% for every increase of 10 °C air temperature. [2]
A w/c ratio higher than 0.60 is not acceptable as fresh concrete becomes "soup" [2] and leads to a higher porosity and to very poor quality hardened concrete as publicly stated by Prof. Gustave Magnel (1889-1955, Ghent University, Belgium) during an official address to American building contractors at the occasion of one of his visits in the ...