An open circuit SCBA typically has three main components: a high-pressure gas storage cylinder, (e.g., 2,216 to 5,500 psi (15,280 to 37,920 kPa), about 150 to 374 atmospheres), a pressure regulator, and a respiratory interface, which may be a mouthpiece, half mask or full-face mask, assembled and mounted on a framed carrying harness.
The pin index safety system uses a face seal between the cylinder valve and the associated yoke clamp. There are two holes in specific positions on the cylinder valve body below the outlet port , in positions associated with the gas mixture, which prevent connection of the cylinder to a yoke or pressure regulator with a mis-matched set of pins.
It provides a method to transfer oxygen breathing gas from a storage tank or other source to the lungs. Oxygen masks may cover only the nose and mouth (oral-nasal mask) or the entire face (full-face mask). oxygen tent An oxygen tent is a delivery method for supplemental oxygen. It consists of a canopy placed over the whole body or part of the ...
A typical nominal regulated gauge pressure from a medical oxygen regulator is 3.4 bars (50 psi), for an absolute pressure of approximately 4.4 bar and a pressure ratio of about 4.4 without back pressure, so they will have choked flow in the metering orifices for a downstream (outlet) pressure of up to about 2.3 bar absolute.
For example, a hydrogen cylinder valve outlet does not fit an oxygen regulator and supply line, which could result in catastrophe. Some fittings use a right-hand thread, while others use a left-hand thread ; left-hand thread fittings are usually identifiable by notches or grooves cut into them, and are usually used for flammable gases.
Medical oxygen storage tanks at the Royal Women's Hospital, Melbourne, Australia. Oxygen may be used for patients requiring supplemental oxygen via mask. Usually accomplished by a large storage system of liquid oxygen at the hospital which is evaporated into a concentrated oxygen supply, pressures are usually around 345–380 kPa (50.0–55.1 psi), [1] [2] or in the UK and Europe, 4–5 bar ...
A typical graph produced when testing the breathing performance of a diving regulator. The breathing performance of regulators is a measure of the ability of a breathing gas regulator to meet the demands placed on it at varying ambient pressures and temperatures, and under varying breathing loads, for the range of breathing gases it may be expected to deliver.
Demand Valve Oxygen Therapy (DVOT) is a way of delivering high flow oxygen therapy using a device that only delivers oxygen when the patient breathes in and shuts off when they breathe out. DVOT is commonly used to treat conditions such as cluster headache , which affects up to four in 1000 people (0.4%), [ 1 ] [ 2 ] [ 3 ] and is a recommended ...