Search results
Results From The WOW.Com Content Network
A three-phase system may be arranged in delta (∆) or star (Y) (also denoted as wye in some areas, as symbolically it is similar to the letter 'Y'). A wye system allows the use of two different voltages from all three phases , such as a 230/400 V system which provides 230 V between the neutral (centre hub) and any one of the phases, and 400 V ...
A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three independent single-phase units. An equivalent ...
In circuit design, the Y-Δ transform, also written wye-delta and also known by many other names, is a mathematical technique to simplify the analysis of an electrical network. The name derives from the shapes of the circuit diagrams , which look respectively like the letter Y and the Greek capital letter Δ .
Column chromatography in chemistry is a chromatography method used to isolate a single chemical compound from a mixture. Chromatography is able to separate substances based on differential absorption of compounds to the adsorbent; compounds move through the column at different rates, allowing them to be separated into fractions.
The Schiff test detects aldehydes; Tollens' reagent tests for aldehydes (known as the silver mirror test) The Zeisel determination tests for the presence of esters or ethers; Lucas' reagent is used to distinguish between primary, secondary and tertiary alcohols. The bromine test is used to test for the presence of unsaturation and phenols.
Procedure to quantify the predictive capability of a docking protocol. edit In the fields of computational chemistry and molecular modelling , scoring functions are mathematical functions used to approximately predict the binding affinity between two molecules after they have been docked .
Wye (Y) and delta (Δ) circuits. There are two basic three-phase configurations: wye (Y) and delta (Δ). As shown in the diagram, a delta configuration requires only three wires for transmission, but a wye (star) configuration may have a fourth wire. The fourth wire, if present, is provided as a neutral and is normally grounded.
A test method is a method for a test in science or engineering, such as a physical test, chemical test, or statistical test. It is a definitive procedure that produces a test result. [ 1 ] In order to ensure accurate and relevant test results, a test method should be "explicit, unambiguous, and experimentally feasible.", [ 2 ] as well as ...