When.com Web Search

  1. Ads

    related to: ducted 30 inch range hood vented out the back view

Search results

  1. Results From The WOW.Com Content Network
  2. Kitchen hood - Wikipedia

    en.wikipedia.org/wiki/Kitchen_hood

    A kitchen hood in a small apartment. A kitchen hood, exhaust hood, hood fan, extractor hood, or range hood is a device containing a mechanical fan that hangs above the stove or cooktop in the kitchen. It removes airborne grease, combustion products, fumes, smoke, heat, and steam from the air by evacuation of the air and filtration. [1]

  3. Fume hood - Wikipedia

    en.wikipedia.org/wiki/Fume_hood

    Energy costs for a typical hood can range from $4,600/year in Los Angeles to $9,300/year in Singapore based on differences in cooling needs. [30] The bulk of the energy that fume hoods are responsible for is the energy needed to heat and/or cool air delivered to the lab space.

  4. Fan (machine) - Wikipedia

    en.wikipedia.org/wiki/Fan_(machine)

    Axial fans with five-inch (125 mm) impellers are also used in larger bathrooms, though they are much less common. Domestic axial extractor fans are unsuitable for duct runs over 3 m or 4 m, depending on the number of bends in the run, as the increased air pressure in longer pipework inhibits the fan's performance.

  5. Bass reflex - Wikipedia

    en.wikipedia.org/wiki/Bass_reflex

    Two-inch port tube installed in the top of a Polk S10 speaker cabinet as part of a DIY audio project. This port is flared. Unlike closed-box loudspeakers, which are nearly airtight, a bass reflex system has an opening called a port or vent cut into the cabinet, generally consisting of a pipe or duct (typically circular or rectangular cross section).

  6. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.

  7. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    A sewer pipe is normally at neutral air pressure compared to the surrounding atmosphere.When a column of waste water flows through a pipe, it compresses air ahead of it in the system, creating a positive pressure that must be released so it does not push back on the waste stream and downstream traps, slow drainage, and induce potential clogs.