Noise curves serve as uniform measuring standards and are referred to by many noise regulations covering a variety of locations from concert halls, rock concerts, lecture rooms and offices to clay target shooting ranges. There are five major methods and standards for noise curves: [4] Noise Criterion Curves (NC) Noise Rating Curves (NR)
If the noise has expected value of zero, as is common, the denominator is its variance, the square of its standard deviation σ N. The signal and the noise must be measured the same way, for example as voltages across the same impedance. Their root mean squares can alternatively be used according to:
A reverberation chamber is used to test the sound absorption coefficients and NRC of a material. The noise reduction coefficient (commonly abbreviated NRC) is a single number value ranging from 0.0 to 1.0 that describes the average sound absorption performance of a material. An NRC of 0.0 indicates the object does not attenuate mid-frequency ...
Noise measurement can also be part of a test procedure using white noise, or some other specialized form of test signal.In audio systems and broadcasting, specific methods are used to obtain subjectively valid results in order that different devices and signal paths may be compared regardless of the inconsistent spectral distribution and temporal properties of the noise that they generate.
Sound Transmission Class (or STC) is an integer rating of how well a building partition attenuates airborne sound.In the US, it is widely used to rate interior partitions, ceilings, floors, doors, windows and exterior wall configurations.
Signal-to-noise ratio (SNR), however, is the ratio between the noise floor and an arbitrary reference level or alignment level. In "professional" recording equipment, this reference level is usually +4 dBu (IEC 60268-17), though sometimes 0 dBu (UK and Europe – EBU standard Alignment level).
ITU-R 468 (originally defined in CCIR recommendation 468-4, therefore formerly also known as CCIR weighting; sometimes referred to as CCIR-1k) is a standard relating to noise measurement, widely used when measuring noise in audio systems.
The noise power from a simple load is equal to kTB, where k is the Boltzmann constant, T is the absolute temperature of the load (for example a resistor), and B is the measurement bandwidth. This makes the noise figure a useful figure of merit for terrestrial systems, where the antenna effective temperature is usually near the standard 290 K ...