When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Time constant - Wikipedia

    en.wikipedia.org/wiki/Time_constant

    In the frequency domain (for example, looking at the Fourier transform of the step response, or using an input that is a simple sinusoidal function of time) the time constant also determines the bandwidth of a first-order time-invariant system, that is, the frequency at which the output signal power drops to half the value it has at low ...

  3. Step response - Wikipedia

    en.wikipedia.org/wiki/Step_response

    This closed-loop gain is of the same form as the open-loop gain: a one-pole filter. Its step response is of the same form: an exponential decay toward the new equilibrium value. But the time constant of the closed-loop step function is τ / (1 + β A 0), so it is faster than the forward amplifier's response by a factor of 1 + β A 0:

  4. RC circuit - Wikipedia

    en.wikipedia.org/wiki/RC_circuit

    These equations show that a series RC circuit has a time constant, usually denoted τ = RC being the time it takes the voltage across the component to either rise (across the capacitor) or fall (across the resistor) to within ⁠ 1 / e ⁠ of its final value. That is, τ is the time it takes V C to reach V(1 − ⁠ 1 / e ⁠) and V R to reach ...

  5. Proportional–integral–derivative controller - Wikipedia

    en.wikipedia.org/wiki/Proportional–integral...

    The dead time θ is the amount of time between when the step change occurred and when the output first changed. The time constant (τ p) is the amount of time it takes for the output to reach 63.2% of the new steady-state value after the step change. One downside to using this method is that it can take a while to reach a new steady-state value ...

  6. Transient response - Wikipedia

    en.wikipedia.org/wiki/Transient_response

    The impulse response and step response are transient responses to a specific input (an impulse and a step, respectively). In electrical engineering specifically, the transient response is the circuit’s temporary response that will die out with time. [ 1 ]

  7. Open-circuit time constant method - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_time_constant...

    An increase in this variable means the higher pole is further above the corner frequency. The y-axis is the ratio of the OCTC (open-circuit time constant) estimate to the true time constant. For the lowest pole use curve T_1; this curve refers to the corner frequency; and for the higher pole use curve T_2. The worst agreement is for τ 1 = τ 2.

  8. Rise time - Wikipedia

    en.wikipedia.org/wiki/Rise_time

    For example, the time interval graphically corresponding to the intercept points of the tangent drawn through the 50% point of the step function response is occasionally used. [12] Another definition, introduced by Elmore (1948, p. 57), [13] uses concepts from statistics and probability theory.

  9. Settling time - Wikipedia

    en.wikipedia.org/wiki/Settling_time

    The settling time for a second order, underdamped system responding to a step response can be approximated if the damping ratio by = ⁡ () A general form is T s = − ln ⁡ ( tolerance fraction × 1 − ζ 2 ) damping ratio × natural freq {\displaystyle T_{s}=-{\frac {\ln({\text{tolerance fraction}}\times {\sqrt {1-\zeta ^{2}}})}{{\text ...