  2. Gyrator–capacitor model - Wikipedia

    en.wikipedia.org/wiki/Gyrator–capacitor_model

    The transformer in this example has three primary windings and three secondary windings. The magnetic circuit is split into seven reluctance or permeance elements. Each winding is modeled by a gyrator. The gyration resistance of each gyrator is equal to the number of turns on the associated winding. Each permeance element is modeled by a capacitor.

  3. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.

  4. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    The number is in units of 30 degrees. For example, a transformer with a vector group of Dy1 has a delta-connected HV winding and a wye-connected LV winding. The phase angle of the LV winding lags the HV by 30 degrees. Note that the high-voltage (HV) side always comes before the low-voltage (LV) side, regardless of which is the primary winding.

  5. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    Nine-winding, three-phase transformers typically have three primaries and six identical secondary windings, which can be used in zigzag winding connection as pictured. [1] A conventional six-winding, grounding transformer or zigzag bank, [1] with the same winding and core quantity as a conventional three-phase transformer, can also be used in ...

  6. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    In contrast to the parallel shunt component, the series component in the circuit diagram represents the winding losses due to the resistance of the coil windings of the transformer. Current, voltage and power are measured at the primary winding to ascertain the admittance and power-factor angle.

  7. Coil winding technology - Wikipedia

    en.wikipedia.org/wiki/Coil_winding_technology

    Consequently, flyer-winding is particularly used if a thin wire and thus high numbers of windings are expected in combination with a medium and high voltage application. Therefore, it is typically used with “white goods”, such as e.g. household applications, or in general domestic engineering with an operating voltage of 230 V.

  8. Copper loss - Wikipedia

    en.wikipedia.org/wiki/Copper_loss

    For low-frequency applications, the power loss can be minimized by employing conductors with a large cross-sectional area, made from low-resistivity metals.With high-frequency currents, the proximity effect and skin effect cause the current to be unevenly distributed across the conductor, increasing its effective resistance, and making loss calculations more difficult.

  9. Leakage inductance - Wikipedia

    en.wikipedia.org/wiki/Leakage_inductance

    Leakage inductance derives from the electrical property of an imperfectly coupled transformer whereby each winding behaves as a self-inductance in series with the winding's respective ohmic resistance constant. These four winding constants also interact with the transformer's mutual inductance. The winding leakage inductance is due to leakage ...