Ad
related to: skimmed walls drying time for concrete
Search results
Results From The WOW.Com Content Network
Concrete creep is essentially the sagging of concrete over time. Creep and shrinkage of concrete are two physical properties of concrete.The creep of concrete, which originates from the calcium silicate hydrates (C-S-H) in the hardened Portland cement paste (which is the binder of mineral aggregates), is fundamentally different from the creep of metals and polymers.
After sufficient setting and hardening of concrete (after 28 days), the progressive loss of capillary water is also responsible for the "drying shrinkage". It is a continuous and long-term process occurring later during the concrete life when under dry conditions the larger pores of concrete are no longer completely saturated by water. Thermal ...
Concrete has a very low coefficient of thermal expansion, and as it matures concrete shrinks. All concrete structures will crack to some extent, due to shrinkage and tension. Concrete which is subjected to long-duration forces is prone to creep. The density of concrete varies, but is around 2,400 kilograms per cubic metre (150 lb/cu ft). [1]
The alkali–silica reaction (ASR), also commonly known as concrete cancer, [3] is a deleterious internal swelling reaction that occurs over time in concrete between the highly alkaline cement paste and the reactive amorphous (i.e., non-crystalline) silica found in many common aggregates, given sufficient moisture.
E.g. A 10-year-old concrete slab can contain more moisture than a 28-day-old slab! Conversely, a self-drying concrete blend consumes all of its mix water with a water:cement ratio of up to 0.6, maintaining good workability while allowing flooring to be installed before it is completely dry.
Saturated surface dry (SSD) is defined as the condition of an aggregate in which the surfaces of the particles are "dry" (i.e., surface adsorption would no longer take place), but the inter-particle voids are saturated with water. In this condition aggregates will not affect the free water content of a composite material. [1] [2]
Image credits: Sasha Weilbaker #7 Solar Panels. While both solar panels and plant leaves harvest energy from the sun, a team at Princeton University took biomimicry in solar panels a step further ...
For a brick structure, the panel should not be any bigger than 3' x 3'. For other masonry units, the test panel can be a little larger. It is also important to pick the right season to do the repointing. Extremely high or low temperatures can cause rapid drying which can have negative effects on the mortar, masonry units, and the structure ...