Search results

  1. Results From The WOW.Com Content Network
  2. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    Controls for the reclosers range from the original electromechanical systems to digital electronics with metering and SCADA functions. The ratings of reclosers run from 2.4–38 kV for load currents from 10–1200 A and fault currents from 1–16 kA. [7] [8] On a 3-phase circuit, a recloser is more beneficial than three separate fuse cutouts.

  3. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    Single-wire earth return (SWER) or single-wire ground return is a single-wire transmission line which supplies single-phase electric power from an electrical grid to remote areas at lowest cost. The earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire ) to act as a ...

  4. Talk:Recloser - Wikipedia

    en.wikipedia.org/wiki/Talk:Recloser

    We want to be a little careful - reclosers are only used on distribution circuits, not on the "grid" (high voltage transmission). True, some circuit breakers on transmission may automatically reclose but that's a special-purpose application and HV transmission circuit breakers aren't called "reclosers".

  5. Substation - Wikipedia

    en.wikipedia.org/wiki/Substation

    A circuit breaker is used as a protection device to interrupt fault currents automatically, and may be used to switch loads on and off, or to cut off a line when power is flowing in the 'wrong' direction. When a large fault current flows through the circuit breaker, this is detected through the use of current transformers. The magnitude of the ...

  6. Defense Supply Center, Columbus - Wikipedia

    en.wikipedia.org/wiki/Defense_Supply_Center...

    The Defense Electronics Supply Center, Columbus (DSCC), is one of three Inventory Control Points of the Defense Logistics Agency. The major organization on base is known as DLA Land and Maritime . Defense Finance and Accounting Service (DFAS) is also a major tenant on base.

  7. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  8. Vacuum interrupter - Wikipedia

    en.wikipedia.org/wiki/Vacuum_interrupter

    In 1956, Hugh C. Ross at Jennings Radio Manufacturing Corporation revolutionized the high-frequency-circuit vacuum switch and produced a vacuum switch with a rating of 15 kV at 200 A. Five years later, Thomas H. Lee at General Electric produced the first vacuum circuit breakers [2] [3] with a rated voltage of 15 kV at short-circuit breaking ...

  9. Transfer switch - Wikipedia

    en.wikipedia.org/wiki/Transfer_switch

    Some transfer switches are manual, in that an operator effects the transfer by throwing a switch, while others are automatic and trigger when they sense one of the sources has lost or gained power. An Automatic Transfer Switch (ATS) is often installed where a backup generator is located, so that the generator may provide temporary electrical ...