When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Power system simulation - Wikipedia

    en.wikipedia.org/wiki/Power_system_simulation

    Load-flow calculation is also the basis of all further network studies, such as motor start-up or investigation of scheduled or unscheduled outages of equipment within the outage simulation. Especially when investigating motor start-up, [ 2 ] the load-flow calculation results give helpful hints, for example, of whether the motor can be started ...

  3. Blocked rotor test - Wikipedia

    en.wikipedia.org/wiki/Blocked_rotor_test

    From this test, short-circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found. It is very important to know a motor's starting torque since if it is not enough to overcome the initial friction of its intended load then it will remain stationary while drawing an ...

  4. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    Inrush current, input surge current, or switch-on surge is the maximal instantaneous input current drawn by an electrical device when first turned on. Alternating-current electric motors and transformers may draw several times their normal full-load current when first energized, for a few cycles of the input waveform.

  5. Electric motor - Wikipedia

    en.wikipedia.org/wiki/Electric_motor

    An industrial electric motor . An electric motor is a machine that converts electrical energy into mechanical energy.Most electric motors operate through the interaction between the motor's magnetic field and electric current in a wire winding to generate force in the form of torque applied on the motor's shaft.

  6. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    As an example, consider the use of a 10 hp, 1760 r/min, 440 V, three-phase induction motor (a.k.a. induction electrical machine in an asynchronous generator regime) as asynchronous generator. The full-load current of the motor is 10 A and the full-load power factor is 0.8. Required capacitance per phase if capacitors are connected in delta:

  7. Induction motor - Wikipedia

    en.wikipedia.org/wiki/Induction_motor

    Under load, the speed drops and the slip increases enough to create sufficient torque to turn the load. For this reason, induction motors are sometimes referred to as "asynchronous motors". [31] An induction motor can be used as an induction generator, or it can be unrolled to form a linear induction motor which can directly generate linear ...

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Utilization factor - Wikipedia

    en.wikipedia.org/wiki/Utilization_factor

    The Load factor is the ratio of the load that a piece of equipment actually draws (time averaged) when it is in operation to the load it could draw (which we call full load). For example, an oversized motor - 15 kW - drives a constant 12 kW load whenever it is on. The motor load factor is then 12/15 = 80%.