A condenser (right) and its respective diaphragm (left) A condenser is an optical lens that renders a divergent light beam from a point light source into a parallel or converging beam to illuminate an object to be imaged. Condensers are an essential part of any imaging device, such as microscopes, enlargers, slide projectors, and telescopes.
Due to Snell's law, the numerical aperture remains the same: NA = n 1 sin θ 1 = n 2 sin θ 2. In optics, the numerical aperture (NA) of an optical system is a dimensionless number that characterizes the range of angles over which the system can accept or emit light.
In optical microscopes a darkfield condenser lens must be used, which directs a cone of light away from the objective lens. To maximize the scattered light-gathering power of the objective lens, oil immersion is used and the numerical aperture (NA) of the objective lens must be less than 1.0. Objective lenses with a higher NA can be used but ...
Memorial in Jena, Germany to Ernst Karl Abbe, who approximated the diffraction limit of a microscope as = , where d is the resolvable feature size, λ is the wavelength of light, n is the index of refraction of the medium being imaged in, and θ (depicted as α in the inscription) is the half-angle subtended by the optical objective lens (representing the numerical aperture).
Phase-contrast microscopy (PCM) is an optical microscopy technique that converts phase shifts in light passing through a transparent specimen to brightness changes in the image. Phase shifts themselves are invisible, but become visible when shown as brightness variations.
HMC systems typically consist of a condenser with a slit aperture, an objective with a slit aperture, and a polariser which is fitted between the condenser and the illumination source and is used to control the degree of contrast. The principle of HMC is used by a number of microscope manufacturers who have introduced their own variants of the ...
The pupil function of an ideal optical system with a circular aperture is a disk of unit radius. The optical transfer function of such a system can thus be calculated geometrically from the intersecting area between two identical disks at a distance of 2 ν {\\displaystyle 2\\nu } , where ν {\\displaystyle \\nu } is the spatial frequency ...
Efforts to improve resolution by increasing the numerical aperture have led to the use of immersion lithography. As further improvements in resolution through wavelength reduction or increases in numerical aperture have become either technically challenging or economically unfeasible, much attention has been paid to reducing the k1-factor.