When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Bus duct - Wikipedia

    en.wikipedia.org/wiki/Bus_duct

    Feeder busway is used to interconnect equipment, such as between a transformer and a switchgear line up. A variant type is a low-impedance busway, which is designed to have lower voltage drop by virtue of close spacing of bus bars, which reduces inductive reactance. A trolley busway provides power to equipment that must be frequently moved.

  3. Electrical busbar system - Wikipedia

    en.wikipedia.org/wiki/Electrical_busbar_system

    Enclosure comparison with normal wiring & with busbar system. Electrical busbar systems [1] (sometimes simply referred to as busbar systems) are a modular approach to electrical wiring, where instead of a standard cable wiring to every single electrical device, the electrical devices are mounted onto an adapter which is directly fitted to a current carrying busbar.

  4. Busbar - Wikipedia

    en.wikipedia.org/wiki/Busbar

    In electric power distribution, a busbar (also bus bar) is a metallic strip or bar, typically housed inside switchgear, panel boards, and busway enclosures for local high current power distribution. They are also used to connect high voltage equipment at electrical switchyards, and low-voltage equipment in battery banks. They are generally ...

  5. Open collector - Wikipedia

    en.wikipedia.org/wiki/Open_collector

    For NPN open collector outputs, the emitter of the NPN transistor is internally connected to ground, [1] so the NPN open collector internally forms either a short-circuit (technically low impedance or "low-Z") connection to the low voltage (which could be ground) when the transistor is switched on, or an open-circuit (technically high impedance ...

  6. Line trap - Wikipedia

    en.wikipedia.org/wiki/Line_trap

    Hence, a line trap unit is inserted between the busbar and connection of coupling capacitor to the line. It is a parallel tuned circuit containing inductance and capacitance. It has low impedance for power frequency and high impedance to carrier frequency. This unit prevents the high frequency carrier signal from entering the neighboring line. [4]

  7. Performance and modelling of AC transmission - Wikipedia

    en.wikipedia.org/wiki/Performance_and_modelling...

    The characteristic impedance or surge impedance (usually written Z 0) of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line; that is, a wave travelling in one direction in the absence of reflections in the other direction. Alternatively and equivalently it can be defined ...

  8. Common Information Model (electricity) - Wikipedia

    en.wikipedia.org/wiki/Common_Information_Model...

    IEC 61970-501 and 61970-452 define an XML format for network model exchanges using RDF. The IEC 61968 series of standards extend CIM to meet the needs of electrical distribution , where related applications include distribution management system , outage management system , planning, metering, work management, geographic information system ...

  9. Current-mode logic - Wikipedia

    en.wikipedia.org/wiki/Current-mode_logic

    Current mode logic (CML), or source-coupled logic (SCL), is a digital design style used both for logic gates and for board-level digital signaling of digital data.. The basic principle of CML is that current from a constant current generator is steered between two alternate paths depending on whether a logic zero or logic one is being represented.