Search results
Results From The WOW.Com Content Network
Feeder busway is used to interconnect equipment, such as between a transformer and a switchgear line up. A variant type is a low-impedance busway, which is designed to have lower voltage drop by virtue of close spacing of bus bars, which reduces inductive reactance. A trolley busway provides power to equipment that must be frequently moved.
Enclosure comparison with normal wiring & with busbar system. Electrical busbar systems [1] (sometimes simply referred to as busbar systems) are a modular approach to electrical wiring, where instead of a standard cable wiring to every single electrical device, the electrical devices are mounted onto an adapter which is directly fitted to a current carrying busbar.
In electric power distribution, a busbar (also bus bar) is a metallic strip or bar, typically housed inside switchgear, panel boards, and busway enclosures for local high current power distribution. They are also used to connect high voltage equipment at electrical switchyards, and low-voltage equipment in battery banks. They are generally ...
Hence, a line trap unit is inserted between the busbar and connection of coupling capacitor to the line. It is a parallel tuned circuit containing inductance and capacitance. It has low impedance for power frequency and high impedance to carrier frequency. This unit prevents the high frequency carrier signal from entering the neighboring line. [4]
A fault current limiter is a nonlinear element which has a low impedance at normal current levels, but presents a higher impedance at fault current levels. Further, this change is extremely rapid, before a circuit breaker can trip a few milliseconds later.
The characteristic impedance or surge impedance (usually written Z 0) of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line; that is, a wave travelling in one direction in the absence of reflections in the other direction. Alternatively and equivalently it can be defined ...
For NPN open collector outputs, the emitter of the NPN transistor is internally connected to ground, [1] so the NPN open collector internally forms either a short-circuit (technically low impedance or "low-Z") connection to the low voltage (which could be ground) when the transistor is switched on, or an open-circuit (technically high impedance ...
For many systems, the terminator is a resistor, with a value chosen to match the characteristic impedance of the transmission line and chosen to have acceptably low parasitic inductance and capacitance at the frequencies relevant to the system. Examples include 75-ohm resistors often used to terminate 75-ohm video transmission coaxial cables.