The negative void coefficient can cause an unplanned reactor power increase in events (such as sudden closure of a streamline valve) where the reactor pressure is suddenly increased. In addition, the negative void coefficient can result in power oscillations in the event of a sudden reduction in core flow, such as might be caused by a ...
Should coolant circulation fail, the neutron moderation effect of the water diminishes due to increased heat which creates steam bubbles which do not moderate neutrons, thus reducing reaction intensity and compensating for loss of cooling, a condition known as negative void coefficient. Later versions of the reactors are encased in massive ...
Such reactors would be described as fitted with such a passive safety component that could – if so designed – render in a reactor a negative void coefficient of reactivity, regardless of the operational property of the reactor in which it is fitted. The feature would only work if it responded faster than an emerging (steam) void and the ...
Also like the pressurized water reactor, a boiling water reactor has a negative void coefficient, that is, the neutron (and the thermal) output of the reactor decreases as the proportion of steam to liquid water increases inside the reactor.
Thus the BWR has a negative void coefficient. Reactor pressure in a BWR is controlled by the main turbine or main steam bypass valves. Unlike a PWR, where the turbine steam demand is set manually by the operators, in a BWR, the turbine valves will modulate to maintain reactor pressure at a setpoint.
The light-water reactor ... This capability is known as a negative void coefficient of reactivity. ... known as the negative temperature coefficient of reactivity, ...
This is measured by the coolant void coefficient. Most modern nuclear power plants have a negative void coefficient, indicating that as water turns to steam, power instantly decreases. Two exceptions are the Soviet RBMK and the Canadian CANDU. Boiling water reactors, on the other hand, are designed to have steam voids inside the reactor vessel.
While with typical CANDU derived fuel bundles, the reactor design has a slightly positive Void coefficient of reactivity, the Argentina designed CARA fuel bundles used in Atucha I, are capable of the preferred negative coefficient. [4]