When.com Web Search

  1. Ads

    related to: 100 psi fire extinguisher gauges

Search results

  1. Results From The WOW.Com Content Network
  2. Fire hydrant - Wikipedia

    en.wikipedia.org/wiki/Fire_hydrant

    A fire hydrant, fireplug, [1] firecock (archaic), [2] hydrant riser or Johnny Pump [3] [better source needed] is a connection point by which firefighters can tap into a water supply. It is a component of active fire protection. Underground fire hydrants have been used in Europe and Asia since at least the 18th century. Above-ground pillar-type ...

  3. Fire hose - Wikipedia

    en.wikipedia.org/wiki/Fire_hose

    It retains its round cross-section when it is not under pressure and is usually carried on a reel on the fire pumper, rather than being stored flat. Booster hose comes in 0.75 and 1.0 in (19 and 25 mm) nominal inside diameters and is designed to operate at pressures up to 800 psi (5,520 kPa). The standard length is 100 ft (30.48 m). [13]

  4. Fire extinguisher - Wikipedia

    en.wikipedia.org/wiki/Fire_extinguisher

    An empty fire extinguisher which was not replaced for years. Most countries in the world require regular fire extinguisher maintenance by a competent person to operate safely and effectively, as part of fire safety legislation. Lack of maintenance can lead to an extinguisher not discharging when required, or rupturing when pressurized.

  5. ABC dry chemical - Wikipedia

    en.wikipedia.org/wiki/ABC_dry_chemical

    Dry chemical powder is used on all classes of fires. Dry chemical powder puts out the fire by coating the burning material with a thin layer of dust, thereby separating the fuel from the oxygen in the air. The powder also works to interrupt the chemical reaction of fire, so these extinguishers are extremely effective at putting out the fire.

  6. Standpipe (firefighting) - Wikipedia

    en.wikipedia.org/wiki/Standpipe_(firefighting)

    External access point for fire sprinkler and dry standpipe at a building in San Francisco, US Antique wet standpipe preserved at Edison and Ford Winter Estates. A standpipe or riser is a type of rigid water piping which is built into multi-story buildings in a vertical position, or into bridges in a horizontal position, to which fire hoses can be connected, allowing manual application of water ...

  7. Hydrostatic test - Wikipedia

    en.wikipedia.org/wiki/Hydrostatic_test

    A structurally weakened fire extinguisher can malfunction or even burst when it is needed the most. To maintain the quality and safety of this product, hydrostatic testing is utilized. All critical components of the fire extinguisher should be tested to ensure proper function.