Xchanger Inc, webpage Calculator for SCFM, NM3/hr, lb/hr, kg/hr, ACFM & M3/hr gas flows. onlineflow.de, webpage Online calculator for conversion of volume, mass and molar flows (SCFM, MMSCFD, Nm3/hr, kg/s, kmol/hr and more) ACFM versus SCFM for ASME AG-1 HEPA Filters; SCFM (Standard CFM) vs. ACFM (Actual CFM) (Specifically for air flows only)
The relationship between gallons per minute (gpm) and fixture unit is not constant, but varies with the number of fixture units. For example, 1000 FU is equivalent to 220 US gallons per minute (0.014 m 3 /s) while 2000 FU represents only 330 US gallons per minute (0.021 m 3 /s), about 1.5 times the flow rate.
Standard cubic centimeters per minute (SCCM) is a unit used to quantify the flow rate of a fluid. 1 SCCM is identical to 1 cm³ STP /min. Another expression of it would be Nml/min. Another expression of it would be Nml/min.
The area required to calculate the volumetric flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface. The vector area is a combination of the magnitude of the area through which the volume passes through, A , and a unit vector normal to the area, n ^ {\displaystyle {\hat {\mathbf {n} }}} .
One GGE of natural gas is 126.67 cubic feet (3.587 m 3) at standard conditions. This volume of natural gas has the same energy content as one US gallon of gasoline (based on lower heating values : 900 BTU/cu ft (9.3 kWh/m 3 ) of natural gas and 114,000 BTU/US gal (8.8 kWh/L) for gasoline).
The area required to calculate the mass flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface, e.g. for substances passing through a filter or a membrane, the real surface is the (generally curved) surface area of the filter, macroscopically - ignoring the area spanned by the holes in the filter/membrane ...
References will be made to "actual" flow rate through a meter and "standard" or "base" flow rate through a meter with units such as acm/h (actual cubic meters per hour), sm 3 /sec (standard cubic meters per second), kscm/h (thousand standard cubic meters per hour), LFM (linear feet per minute), or MMSCFD (million standard cubic feet per day).
Note that the m³ gas conversion factor takes into account a difference in the standard temperature base for measurement of gas volumes in metric and imperial units. The standard temperature for metric measurement is 15 degrees Celsius (i.e. 59 degrees Fahrenheit) while for English measurement the standard temperature is 60 °F.