When.com Web Search

  1. Ads

    related to: transformer with 2 secondary windings and 6 wire cable and 1 wall switch

Search results

  1. Results From The WOW.Com Content Network
  2. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    For example, a 1000:1 CT provides an output current of 1 amperes when 1000 amperes flow through the primary winding. Standard secondary current ratings are 5 amperes or 1 ampere, compatible with standard measuring instruments. The secondary winding can be single ratio or have several tap points to provide a range of ratios. Care must be taken ...

  3. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    A transformer supplying a three-wire distribution system has a single-phase input (primary) winding. The output (secondary) winding has a center tap connected to a grounded neutral. As shown in Fig. 1, either end to center has half the voltage of end-to-end. Fig. 2 illustrates the phasor diagram of the output voltages for a split-phase transformer.

  4. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    A "transformer bank", widely used in North America: three single-phase transformers connected to make a 3-phase transformer. The low-voltage secondary windings are attached to three or four terminals on the transformer's side. In North American residences and small businesses, the secondary is often the split-phase 120/240-volt system. The 240 ...

  5. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three independent single-phase units.

  6. Flyback transformer - Wikipedia

    en.wikipedia.org/wiki/Flyback_transformer

    When the switch is switched on, the primary inductance causes the current to build up in a ramp. An integral diode connected in series with the secondary winding prevents the formation of a secondary current that would eventually oppose the primary current ramp. [1] When the switch is turned off, the current in the primary falls to zero.

  7. Induction coil - Wikipedia

    en.wikipedia.org/wiki/Induction_coil

    An induction coil consists of two coils of insulated wire wound around a common iron core (M). [1] [7] One coil, called the primary winding (P), is made from relatively few (tens or hundreds) turns of coarse wire. [7] The other coil, the secondary winding, (S) typically consists of up to a million turns of fine wire (up to 40 gauge). [8] [1] [7]

  8. Quadrature booster - Wikipedia

    en.wikipedia.org/wiki/Quadrature_booster

    400 MVA 220/155 kV phase-shifting transformer.. A phase angle regulating transformer, phase angle regulator (PAR, American usage), phase-shifting transformer, phase shifter (West coast American usage), or quadrature booster (quad booster, British usage), is a specialised form of transformer used to control the flow of real power on three-phase electric transmission networks.

  9. Scott-T transformer - Wikipedia

    en.wikipedia.org/wiki/Scott-T_transformer

    Standard Scott Connection 3 φ to 2 φ. Assuming the desired voltage is the same on the two and three phase sides, the Scott-T transformer connection (shown right) consists of a centre-tapped 1:1 ratio main transformer, T1, and a √ 3 /2(≈86.6%) ratio teaser transformer, T2. The centre-tapped side of T1 is connected between two of the phases ...