Ad
related to: refrigerant r numbering system diagram
Search results
Results From The WOW.Com Content Network
According to ASHRAE standard 34, the R-number of a chemical refrigerant is assigned systematically according to its molecular structure and has between two and four digits. If there are carbon-carbon multiple bonds, there are four digits in all: the number of these bonds is the first digit and the number of carbon atoms minus one (C-1) is next ...
The R- numbering system was developed by DuPont (which owned the Freon trademark), and systematically identifies the molecular structure of refrigerants made with a single halogenated hydrocarbon. ASHRAE has since set guidelines for the numbering system as follows: [85] R-X 1 X 2 X 3 X 4. X 1 = Number of unsaturated carbon-carbon bonds (omit if ...
R-410A was invented and patented by Allied Signal (now Honeywell) in 1991. [5] Other producers around the world have been licensed to manufacture and sell R-410A. [6] R-410A was successfully commercialized in the air conditioning segment by a combined effort of Carrier Corporation, Emerson Climate Technologies, Inc., Copeland Scroll Compressors (a division of Emerson Electric Company), and ...
Pentafluoroethane is a fluorocarbon with the formula CF 3 CHF 2.Pentafluoroethane is currently used as a refrigerant (known as R-125) and also used as a fire suppression agent in fire suppression systems.
1,2-Dichlorotetrafluoroethane, or R-114, also known as cryofluorane , is a chlorofluorocarbon (CFC) with the molecular formula ClF 2 CCF 2 Cl. Its primary use has been as a refrigerant . It is a non-flammable gas with a sweetish, chloroform -like odor with the critical point occurring at 145.6 °C and 3.26 MPa.
The choice of working fluids is known to have a significant impact on the thermodynamic as well as economic performance of the cycle. A suitable fluid must exhibit favorable physical, chemical, environmental, safety and economic properties such as low specific volume (high density), viscosity, toxicity, flammability, ozone depletion potential (ODP), global warming potential (GWP) and cost, as ...
R-407C is a mixture of hydrofluorocarbons used as a refrigerant. It is a zeotropic blend of difluoromethane (R-32), pentafluoroethane (R-125), and 1,1,1,2-tetrafluoroethane (R-134a). Difluoromethane serves to provide the heat capacity, pentafluoroethane decreases flammability, tetrafluoroethane reduces pressure. [ 1 ]
A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.
Ad