When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Single-unit recording - Wikipedia

    en.wikipedia.org/wiki/Single-unit_recording

    Silicon electrodes are alloy electrodes doped with silicon and an insulating glass cover layer. Silicon technology provides better mechanical stiffness and is a good supporting carrier to allow for multiple recording sites on a single electrode. [31] Tungsten electrodes are very rugged and provide very stable recordings. This allows ...

  3. Electrophysiology - Wikipedia

    en.wikipedia.org/wiki/Electrophysiology

    An electrode introduced into the brain of a living animal will detect electrical activity that is generated by the neurons adjacent to the electrode tip. If the electrode is a microelectrode, with a tip size of about 1 micrometre, the electrode will usually detect the activity of at most one neuron.

  4. Electroanalytical methods - Wikipedia

    en.wikipedia.org/wiki/Electroanalytical_methods

    Potentiometry passively measures the potential of a solution between two electrodes, affecting the solution very little in the process. One electrode is called the reference electrode and has a constant potential, while the other one is an indicator electrode whose potential changes with the sample's composition. Therefore, the difference in ...

  5. Patch clamp - Wikipedia

    en.wikipedia.org/wiki/Patch_clamp

    During a patch clamp recording, a hollow glass tube known as a micropipette or patch pipette filled with an electrolyte solution and a recording electrode connected to an amplifier is brought into contact with the membrane of an isolated cell. Another electrode is placed in a bath surrounding the cell or tissue as a reference ground electrode ...

  6. Error-related negativity - Wikipedia

    en.wikipedia.org/wiki/Error-related_negativity

    The ERN is a sharp negative going signal which begins about the same time an incorrect motor response begins, (response locked event-related potential), and typically peaks from 80 to 150 milliseconds (ms) after the erroneous response begins (or 40–80 ms after the onset of electromyographic activity).

  7. Electrical brain stimulation - Wikipedia

    en.wikipedia.org/wiki/Electrical_brain_stimulation

    Chronic subcortical electrode implant in a laboratory rat used to deliver electrical stimulation to the brain. Electrical brain stimulation (EBS), also referred to as focal brain stimulation (FBS), is a form of electrotherapy and neurotherapy used as a technique in research and clinical neurobiology to stimulate a neuron or neural network in the brain through the direct or indirect excitation ...

  8. Microelectrode - Wikipedia

    en.wikipedia.org/wiki/Microelectrode

    A microelectrode is an electrode used in electrophysiology either for recording neural signals or for the electrical stimulation of nervous tissue (they were first developed by Ida Hyde in 1921). Pulled glass pipettes with tip diameters of 0.5 μm or less are usually filled with 3 molars potassium chloride solution as the electrical conductor.

  9. Auditory brainstem response - Wikipedia

    en.wikipedia.org/wiki/Auditory_brainstem_response

    Analysis is dependent upon the fact that related bioelectric events coincide with the stimulus repetition rate. The specific analysis method is based on the manufacturer's detection algorithm. It occurs in the spectral domain and is composed of specific frequency components that are harmonics of the stimulus repetition rate.