When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Pensky–Martens closed-cup test - Wikipedia

    en.wikipedia.org/wiki/Pensky–Martens_closed-cup...

    This allows the development of an equilibrium between the liquid and the air volume. The ignition source is directed into the cup at regular intervals with simultaneous interruption of stirring. The test concludes upon observation of a flash that spreads throughout the inside of the cup. The corresponding temperature is the liquid's flash point.

  3. Flash point - Wikipedia

    en.wikipedia.org/wiki/Flash_point

    Closed cup testers normally give lower values for the flash point than open cup (typically 5–10 °C or 9–18 °F lower) and are a better approximation to the temperature at which the vapour pressure reaches the lower flammable limit. In addition to the Penskey-Martens flash point testers, other non-equilibrial testers include TAG and Abel ...

  4. HAZMAT Class 3 Flammable liquids - Wikipedia

    en.wikipedia.org/wiki/HAZMAT_Class_3_Flammable...

    A flammable liquid is a liquid having a flash point of not more than 60 °C (140 °F), or any material in a liquid phase with a flash point at or above 37.8 °C (100 °F) that is intentionally heated and offered for transportation or transported at or above its flash point in a bulk packaging. The following exceptions apply:

  5. Cleveland open-cup method - Wikipedia

    en.wikipedia.org/wiki/Cleveland_open-cup_method

    The Cleveland open-cup method is one of three main methods in chemistry for determining the flash point of a petroleum product using a Cleveland open-cup apparatus, also known as a Cleveland open-cup tester. [1] First, the test cup of the apparatus (usually brass) is filled to a certain level with a portion of the product.

  6. NFPA 704 - Wikipedia

    en.wikipedia.org/wiki/NFPA_704

    Liquids having a flash point below 22.8 °C (73 °F) and having a boiling point at or above 37.8 °C (100 °F) or having a flash point between 22.8 and 37.8 °C (73 and 100 °F). 4 Will rapidly or completely vaporize at normal atmospheric pressure and temperature, or is readily dispersed in air and will burn readily (e.g., gasoline , acetylene ...

  7. Flashover - Wikipedia

    en.wikipedia.org/wiki/Flashover

    Flashover occurs when the majority of the exposed surfaces in a space are heated to their autoignition temperature and emit flammable gases (see also flash point). Flashover normally occurs at 500 °C (932 °F) or 590 °C (1,100 °F) for ordinary combustibles and an incident heat flux at floor level of 20 kilowatts per square metre (2.5 hp/sq ft).

  8. Flash evaporation - Wikipedia

    en.wikipedia.org/wiki/Flash_evaporation

    If the throttling valve or device is located at the entry into a pressure vessel so that the flash evaporation occurs within the vessel, then the vessel is often referred to as a flash drum. [1] [2] If the saturated liquid is a single-component liquid (for example, propane or liquid ammonia), a part of the liquid immediately "flashes" into vapor.

  9. Autoignition temperature - Wikipedia

    en.wikipedia.org/wiki/Autoignition_temperature

    The autoignition temperature or self-ignition temperature, often called spontaneous ignition temperature or minimum ignition temperature (or shortly ignition temperature) and formerly also known as kindling point, of a substance is the lowest temperature at which it spontaneously ignites in a normal atmosphere without an external source of ignition, such as a flame or spark. [1]