Search results
Results From The WOW.Com Content Network
A potentiometric surface is the imaginary plane where a given reservoir of fluid will "equalize out to" if allowed to flow. A potentiometric surface is based on hydraulic principles. For example, two connected storage tanks with one full and one empty will gradually fill/drain to the same level. This is because of atmospheric pressure and gravity.
Here the 'IEEE 754 double value' resulting of the 15 bit figure is 3.330560653658221E-15, which is rounded by Excel for the 'user interface' to 15 digits 3.33056065365822E-15, and then displayed with 30 decimals digits gets one 'fake zero' added, thus the 'binary' and 'decimal' values in the sample are identical only in display, the values ...
Typically this equation is used to find the average T and S values near a pumping well, from drawdown data collected during an aquifer test. This is a simple form of inverse modeling, since the result ( s ) is measured in the well, r , t , and Q are observed, and values of T and S which best reproduce the measured data are put into the equation ...
In analytical chemistry, potentiometric titration is a technique similar to direct titration of a redox reaction. It is a useful means of characterizing an acid . No indicator is used; instead the electric potential is measured across the analyte , typically an electrolyte solution.
For general purposes, buffers at pH 4.00 and pH 10.00 are suitable. The pH meter has one calibration control to set the meter reading equal to the value of the first standard buffer and a second control to adjust the meter reading to the value of the second buffer. A third control allows the temperature to be set.
Cross section showing the water table varying with surface topography as well as a perched water table Cross-section of a hillslope depicting the vadose zone, capillary fringe, water table, and the phreatic or saturated zone. (Source: United States Geological Survey.) The water table is the upper surface of the phreatic zone or zone
Potentiometric solid state gas sensors have been generally classified into three broad groups. Type I sensors have an electrolyte containing mobile ions of the chemical species in the gas phase that it is monitoring. The commercial product, YSZ oxygen sensor, [1] is an example of type I.
A user will input a number and the Calculator will use an algorithm to search for and calculate closed-form expressions or suitable functions that have roots near this number. Hence, the calculator is of great importance for those working in numerical areas of experimental mathematics. The ISC contains 54 million mathematical constants.