When.com Web Search

  1. Ad

    related to: transformer winding resistance meter calculator

Search results

  1. Results From The WOW.Com Content Network
  2. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    An ammeter is connected in series with the primary winding. A voltmeter is optional since the applied voltage is the same as the voltmeter reading. Now with the help of a variac , the applied voltage is slowly increased until the ammeter gives a reading equal to the rated current of the HV side.

  3. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    In contrast to the parallel shunt component, the series component in the circuit diagram represents the winding losses due to the resistance of the coil windings of the transformer. Current, voltage and power are measured at the primary winding to ascertain the admittance and power-factor angle.

  4. Electrical isolation test - Wikipedia

    en.wikipedia.org/wiki/Electrical_isolation_test

    A minimum acceptable resistance value is usually specified (typically in the mega ohm (MΩ) range per circuit tested). Multiple circuits having a common return may be tested simultaneously, provided the minimum allowable resistance value is based on the number of circuits in parallel. Five basic isolation test configurations exist: [3]

  5. Leakage inductance - Wikipedia

    en.wikipedia.org/wiki/Leakage_inductance

    Leakage inductance derives from the electrical property of an imperfectly coupled transformer whereby each winding behaves as a self-inductance in series with the winding's respective ohmic resistance constant. These four winding constants also interact with the transformer's mutual inductance. The winding leakage inductance is due to leakage ...

  6. Multimeter - Wikipedia

    en.wikipedia.org/wiki/Multimeter

    As an example, a meter movement that required 1 mA for full-scale deflection, with an internal resistance of 500 Ω, would, on a 10 V range of the multimeter, have 9,500 Ω of series resistance. [20] For analog current ranges, matched low-resistance shunts are connected in parallel with the meter movement to divert most of the current around ...

  7. Linear variable differential transformer - Wikipedia

    en.wikipedia.org/wiki/Linear_variable...

    Cutaway view of an LVDT. Current is driven through the primary coil at A, causing an induction current to be generated through the secondary coils at B.. The linear variable differential transformer (LVDT) – also called linear variable displacement transformer, [1] linear variable displacement transducer, [2] or simply differential transformer [3] – is a type of electrical transformer [4 ...

  8. Mean Length Turn - Wikipedia

    en.wikipedia.org/wiki/Mean_Length_Turn

    Mean Length Turn, sometimes Mean Length per Turn is the mean length of winding turn in a coil, usually referred to by the initials MLT.The dimensions of a coil former or bobbin define the MLT of a full wound coil. [1]

  9. Tesla coil - Wikipedia

    en.wikipedia.org/wiki/Tesla_coil

    The supply transformer (T) secondary winding is connected across the primary tuned circuit. It might seem that the transformer would be a leakage path for the RF current, damping the oscillations. However its large inductance gives it a very high impedance at the resonant frequency, so it acts as an open circuit to the oscillating current.