Data centers typically have raised flooring made up of 60 cm (2 ft) removable square tiles. The trend is towards 80–100 cm (31–39 in) void to cater for better and uniform air distribution. These provide a plenum for air to circulate below the floor, as part of the air conditioning system, as well as providing space for power cabling.
UFAD is also common in command centers, IT data centers and Server rooms that have large cooling loads from electronic equipment and requirements for routing power and data cables. The ASHRAE Underfloor Air Distribution Design Guide suggests that any building considering a raised floor for cable distribution should consider UFAD. [8]
A data center is a building, a dedicated space within a building, ... A raised floor standards guide named GR-2930 was developed by Telcordia Technologies, ...
Access flooring - cables are installed below a raised floor. In Floor Cellular Raceway Systems - utilize enclosed steel raceways located within a concrete floor slab to distribute power, data, and telecom cabling throughout a space to any location where these services are required today – and where they may be required in the future.
Space between the structural ceiling and the dropped ceiling or under a raised floor is typically considered plenum; however, some drop-ceiling designs create a tight seal that does not allow for airflow and therefore may not be considered a plenum air-handling space. [1] [2]
A grommet is a ring or edge strip inserted into a hole through thin material, typically a sheet of textile fabric, sheet metal or composite of carbon fiber, wood or honeycomb. Grommets are generally flared or collared on each side to keep them in place, and are often made of metal , plastic , or rubber .
Floor Level Floor Level of an existing or proposed building or concrete pad FN or F/N: flag note, flagnote; find number: 1. Flagnote: A flagnote is a note that is called out in specific spots in the field of the drawing. It is numbered with a stylized flag symbol surrounding the number (or sometimes a delta symbol). A general note applies ...
A meet-me room (MMR) is a place within a colocation center (or carrier hotel) where telecommunications companies can physically connect to one another and exchange data without incurring local loop fees. [1] Services provided across connections in an MMR may be voice circuits, data circuits, or Internet Protocol traffic.