Blood glucose monitoring is the use of a glucose meter for testing the concentration of glucose in the blood (glycemia). Particularly important in diabetes management, a blood glucose test is typically performed by piercing the skin (typically, via fingerstick) to draw blood, then applying the blood to a chemically active disposable 'test-strip'.
Glucose homeostasis, when operating normally, restores the blood sugar level to a narrow range of about 4.4 to 6.1 mmol/L (79 to 110 mg/dL) (as measured by a fasting blood glucose test). [10] The global mean fasting plasma blood glucose level in humans is about 5.5 mmol/L (100 mg/dL); [11] [5] however, this level fluctuates throughout the day ...
Glycated hemoglobin. Glycated hemoglobin, glycohemoglobin, glycosylated hemoglobin is a form of hemoglobin (Hb) that is chemically linked to a sugar. Several types of glycated hemoglobin measures exist, of which HbA1c, or simply A1c, is a standard single test. [1] Most monosaccharides, including glucose, galactose, and fructose, spontaneously ...
measure concentration of glucose in the blood. A glucose meter, also referred to as a " glucometer ", [1] is a medical device for determining the approximate concentration of glucose in the blood. It can also be a strip of glucose paper dipped into a substance and measured to the glucose chart. It is a key element of glucose testing, including ...
A continuous glucose monitor (CGM) is a device used for monitoring blood glucose on a continual basis instead of monitoring glucose levels periodically by drawing a drop of blood from a finger. This is known as continuous glucose monitoring. CGMs are used by people who treat their diabetes with insulin, for example people with type 1 diabetes ...
Hyperglycemia or Hyperglycaemia is a condition in which an excessive amount of glucose (glucotoxicity) circulates in the blood plasma. This is generally a blood sugar level higher than 11.1 mmol/L (200 mg/dL), but symptoms may not start to become noticeable until even higher values such as 13.9–16.7 mmol/L (~250–300 mg/dL).
Noninvasive glucose monitoring (NIGM), called Noninvasive continuous glucose monitoring when used as a CGM technique, is the measurement of blood glucose levels, required by people with diabetes to prevent both chronic and acute complications from the disease, without drawing blood, puncturing the skin, or causing pain or trauma.
Biomarkers of diabetes. Diabetes mellitus (DM) is a type of metabolic disease characterized by hyperglycemia. It is caused by either defected insulin secretion or damaged biological function, or both. The high-level blood glucose for a long time will lead to dysfunction of a variety of tissues. [1]