When.com Web Search

  1. Ads

    related to: is mc cable plenum rated

Search results

  1. Results From The WOW.Com Content Network
  2. Plenum cable - Wikipedia

    en.wikipedia.org/wiki/Plenum_cable

    The fire requirements on riser cable are not as strict. Thus, plenum cable can always replace riser cable, but riser cable cannot replace plenum cable in plenum spaces. Both plenum and riser cables commonly include a rope or polymer filament with high tensile strength, which helps support the weight of the cable when it is dangling in an open ...

  3. Mineral-insulated copper-clad cable - Wikipedia

    en.wikipedia.org/wiki/Mineral-insulated_copper...

    Mineral-insulated copper-clad cable is a variety of electrical cable made from copper conductors inside a copper sheath, insulated by inorganic magnesium oxide powder. The name is often abbreviated to MICC or MI cable, and colloquially known as pyro (because the original manufacturer and vendor for this product in the UK was a company called ...

  4. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    Distinct from ductwork as a plenum is part of the structure itself. Cable and piping within a plenum must be properly rated for its fire and smoke indices. See also: plenum chamber

  5. Dropped ceiling - Wikipedia

    en.wikipedia.org/wiki/Dropped_ceiling

    While twisted pair cable for networking and telephone service is the most common form of plenum cable, coaxial cable also needs to be plenum-rated for safety. High-voltage electrical equipment (generally regarded as being over 50 V) is not permitted to be exposed in the plenum space above a drop ceiling but must be enclosed in conduit or ...

  6. Microducts - Wikipedia

    en.wikipedia.org/wiki/Microducts

    Be compatible with existing construction designs and building configurations for both riser- and plenum-rated applications, including cable blowing apparatus. Allow cables to be safely deployed through pull lines or strings using less than 50 lbs of force, and through cable blowing techniques at typical deployment speeds of 100–200 feet per ...

  7. ANSI/TIA-568 - Wikipedia

    en.wikipedia.org/wiki/ANSI/TIA-568

    ANSI/TIA-568 is a technical standard for commercial building cabling for telecommunications products and services. The title of the standard is Commercial Building Telecommunications Cabling Standard and is published by the Telecommunications Industry Association (TIA), a body accredited by the American National Standards Institute (ANSI).

  8. Electrical equipment in hazardous areas - Wikipedia

    en.wikipedia.org/wiki/Electrical_equipment_in...

    Many items of EEx rated equipment will employ more than one method of protection in different components of the apparatus. These would be then labeled with each of the individual methods. For example, a socket outlet labeled EEx'de' might have a case made to EEx 'e' and switches that are made to EEx 'd'.

  9. MC4 connector - Wikipedia

    en.wikipedia.org/wiki/MC4_connector

    The MC4 connector is UL rated at 1500 V DC and up to 95 A with the 6AWG PV Cable. MC4-Evo 2 has both UL and IEC certification ratings of 1500 V DC and up to 70 A with 10mm² PV Cable, depending on the conductor size used in pairs.