When.com Web Search

  1. Ads

    related to: 8 3 wire amp rating

Search results

  1. Results From The WOW.Com Content Network
  2. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    Consecutive AWG wire sizes thicker than No. 1 wire are designated by the number of zeros: No. 0, often written 1/0 and referred to as "one-aught" or "single-aught" wire; No. 00, often written 2/0 and referred to as "two-aught" or "double-aught" wire; No. 000, often written 3/0 and referred to as "three-aught" or "triple-aught" wire; and so on.

  3. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    For example, the United States National Electrical Code, Table 310.15(B)(16), specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30 °C, the conductor surface temperature allowed to be 75 °C. A single insulated conductor ...

  4. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    The standard includes preferred current ratings and wire gauges for both International (deemed Series I) and North American (deemed Series II) applications. Series I preferred current ratings (in amps) are: 16, 32, 63, 125, 250, 400, 630 and 800, with wire gauges specified as mm 2 .

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  6. Standard wire gauge - Wikipedia

    en.wikipedia.org/wiki/Standard_wire_gauge

    A standard wire gauge. The British Standard Wire Gauge, often referred to as the Standard Wire Gauge or simply SWG, is a unit used to denote wire gauge (size) as defined by BS 3737:1964, a standard that has since been withdrawn. It is also known as the Imperial Wire Gauge or British Standard Gauge. Although its use has significantly declined ...

  7. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    As an example, the 5-15R is the common 125 V two-pole, three-wire receptacle rated for 15 A. The L5-15R, while sharing the same electrical rating, is a locking design that is not physically compatible with the straight-blade 5-15 design. The 5-30R has the same two-pole, three-wire configuration and 125 V rating, but is rated for 30 A.