When.com Web Search

  1. Ads

    related to: 1 hour fire rated caulking hilti concrete mix

Search results

  1. Results From The WOW.Com Content Network
  2. List of fire-retardant materials - Wikipedia

    en.wikipedia.org/wiki/List_of_fire-retardant...

    In the United Kingdom, after two significant construction fires which resulted in a combined loss of £1,500 million, The Joint Code of Practice was introduced by the Fire Protection Association (FPA), the UK's national fire safety organisation, [1] to prevent fires on buildings undergoing construction work.

  3. Firestop - Wikipedia

    en.wikipedia.org/wiki/Firestop

    They receive a fire rating by combining materials in an arrangement specific to the item (a pipe or cable, for example) penetrating the fire-rated wall or floor and the construction arrangement of the fire-rated wall or floor. A two-hour-rated pipe-penetration firestop may consist of a layer of caulking over packed mineral wool. The arrangement ...

  4. Firewall (construction) - Wikipedia

    en.wikipedia.org/wiki/Firewall_(construction)

    A fire barrier wall, or a fire partition, is a fire-rated wall assembly that are not structurally self-sufficient. [ 2 ] Fire barrier walls are typically continuous from an exterior wall to an exterior wall, or from a floor below to a floor or roof above, or from one fire barrier wall to another fire barrier wall, having a fire resistance ...

  5. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    This rating is the requirement in data safes and vault structures for protecting digital information on magnetic media or hard drives. Temperatures inside the protected chamber must be held below 125 °F (52 °C) for the time period specified, such as Class 125-2 Hour, with temperatures up to 2,000 °F (1,090 °C) outside the vault.

  6. Sealant - Wikipedia

    en.wikipedia.org/wiki/Sealant

    Self-leveling silicone firestop system used around pipe through-penetration in a two-hour fire-resistance rated concrete floor assembly. Sealant is a substance used to block the passage of fluids through openings in materials, [1] a type of mechanical seal. In building construction sealant is sometimes synonymous with caulk (especially if ...

  7. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    Canada de-rates closures, where, for instance a 2-hour closure is acceptable for use in a 3-hour fire separation, so long as the fire separation is not an occupancy separation or firewall. The lowered rating is then referred to as a fire protection rating, both for firestops, unless they contain plastic pipes and regular closures. Firestops

  8. Penetration (firestop) - Wikipedia

    en.wikipedia.org/wiki/Penetration_(firestop)

    A penetration, in firestopping, is an opening, such as one created by the use of a cast-in-place sleeve, in a wall or floor assembly required to have a fire-resistance rating, for the purpose of accommodating the passage of a mechanical, electrical, or structural penetrant. [1] The penetration may or may not contain a firestop system.

  9. Gypsum concrete - Wikipedia

    en.wikipedia.org/wiki/Gypsum_concrete

    Gypsum concrete is lightweight and fire-resistant. A 1.5-inch slab of gypsum concrete weighs 13 pounds per square foot versus 18 pounds per square foot for regular concrete. [10] Even though gypsum concrete weighs less, it still has the same compressive strength as regular concrete, based on its application as underlayment or top coat flooring ...