Search results
Results From The WOW.Com Content Network
The pupil function or aperture function describes how a light wave is affected upon transmission through an optical imaging system such as a camera, microscope, or the human eye. More specifically, it is a complex function of the position in the pupil [ 1 ] or aperture (often an iris ) that indicates the relative change in amplitude and phase ...
Etendue for a differential surface element in 2D (left) and 3D (right).. An infinitesimal surface element, dS, with normal n S is immersed in a medium of refractive index n.The surface is crossed by (or emits) light confined to a solid angle, dΩ, at an angle θ with the normal n S.
The emergent light at the eyepiece then fills the eye's pupil, meaning no loss of brightness at night due to using such binoculars (assuming perfect transmission). In daylight, when the eye's pupil is only 4 mm in diameter, over half the light will be blocked by the iris and will not reach the retina. However, the loss of light in the daytime ...
Although one typically thinks of an image as planar, or two-dimensional, the imaging system will produce a three-dimensional intensity distribution in image space that in principle can be measured. e.g. a two-dimensional sensor could be translated to capture a three-dimensional intensity distribution.
The pupillary light reflex (PLR) or photopupillary reflex is a reflex that controls the diameter of the pupil, in response to the intensity of light that falls on the retinal ganglion cells of the retina in the back of the eye, thereby assisting in adaptation of vision to various levels of lightness/darkness.
It involves the automatic constriction and dilation of the pupils in response to changes in light intensity or accommodation. With an automated pupillometer and an algorithm analyzing the pupil continuously for 5 seconds, the Quantitative Pupillometry Index (QPi) can measure pupillary reactivity and provides a numerical value.
Classification of the different kinds of optical autocorrelation. In optics, various autocorrelation functions can be experimentally realized. The field autocorrelation may be used to calculate the spectrum of a source of light, while the intensity autocorrelation and the interferometric autocorrelation are commonly used to estimate the duration of ultrashort pulses produced by modelocked lasers.
A camera lens adjusted for large and small aperture. The visible opening is the entrance pupil of the lens. The apparent location of the anatomical pupil of a human eye (black circle) is the eye's entrance pupil location. The outside world appears to be seen from the point at the center of the entrance pupil.