When.com Web Search

  1. Ad

    related to: how to duct an erv 2 box with water connection 1 hour wall

Search results

  1. Results From The WOW.Com Content Network
  2. Turning vanes (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Turning_vanes_(HVAC)

    HVAC turning vanes are sheet metal devices inside of mechanical ductwork used to smoothly direct air inside a duct where there is a change in direction, by reducing resistance and turbulence. See also

  3. Air-mixing plenum - Wikipedia

    en.wikipedia.org/wiki/Air-mixing_plenum

    An air handling unit used for the heating and cooling air: (1) supply air (2) fan section (3) vibration isolator (4) cooling coil (5) filter (6) mixed air duct. Air supply to a building is generally performed by an air handling unit. The process may include filtering, heating, cooling, humidification, or dehumidification, all of which consume ...

  4. Central vacuum cleaner - Wikipedia

    en.wikipedia.org/wiki/Central_vacuum_cleaner

    However, that manufacturer has also switched to the de facto industry standard size of 2-inch (5.1 cm) outside diameter piping and corresponding fittings. In most cases, the end user need not be aware of the piping size in a central vacuum system, but the piping size must be considered when extending, modifying, or repairing a system.

  5. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.

  6. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.

  7. Heat recovery ventilation - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_ventilation

    Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...

  8. Constant air volume - Wikipedia

    en.wikipedia.org/wiki/Constant_air_volume

    [2] The terminal reheat system cools the air in the air handling unit down to the lowest possible needed temperature within its zone of spaces. This supplies a comfortable quality to the space, but wastes energy. The mixed air system has two air streams, typically one for the coldest and one for the hottest needed air temperature in the zone.

  9. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    An unlouvered wall register, which allows circulation of air from one floor to another. Registers vary in size with the heating and cooling requirements of the room. [5] If a register is too small, the HVAC system will need to push air through the ducts at a faster rate in order to achieve the desired heating or cooling.